Service manual
VRV IV+ Heat Pump
English
Service manual
VRV IV+ Heat Pump
RYYQ8U7Y1B*
RYYQ10U7Y1B*
RYYQ12U7Y1B*
RYYQ14U7Y1B*
RYYQ16U7Y1B*
RYYQ18U7Y1B*
RYYQ20U7Y1B*
RYMQ8U7Y1B*
RYMQ10U7Y1B*
RYMQ12U7Y1B*
RYMQ14U7Y1B*
RYMQ16U7Y1B*
RYMQ18U7Y1B*
RYMQ20U7Y1B*
RXYQ8U7Y1B*
RXYQ10U7Y1B*
RXYQ12U7Y1B*
RXYQ14U7Y1B*
RXYQ16U7Y1B*
RXYQ18U7Y1B*
RXYQ20U7Y1B*
https://daikin-p.ru/catalog/vrv-daikn/naruzhnye-vrv-bloki-daikin
2
Table of Contents
Table of Contents
4
General Operation
7
Troubleshooting
9
To Access Push Buttons and 7-Segment Display
9
Via Service Checker Type 3
9
Via the Indoor Unit Remote Controller BRC1H
9
Via the Outdoor Unit
10
Via the Wired Remote Control BRC1E
10
Via the Wireless Controller BRC4/7
11
Via the Wired Remote Control BRC1D
11
Error Based Troubleshooting
12
E1-01 - Outdoor Unit Main PCB A1P Error
12
E1-02 - Outdoor Unit Main PCB A1P Error
12
E2-01-02-03 - Current Leak Detection
12
E2-06-07-08 - Open Circuit on Earth Leakage
13
Detection Core
13
E3-01-03-05 - Actuation of High Pressure Switch
13
E3-02-04-06 - High Pressure Error
14
E3-07 - High Pressure Switch Reset Error
14
E3-13-14-15 - Liquid Stop Valve Check Error
14
E3-18 - Actuation of High Pressure Switch During Test Run
15
E3-20-21-22 - Jumper Open on Main PCB
15
E4-01-02-03 - Low Pressure Error
15
E5-01-02-03 - Compressor Overload Error
16
E5-07-08-09 - Compressor Overload Error
17
E6-17-19-21 - Inverter Overcurrent Error
17
E6-18-20-22 - Inverter Overcurrent Error
18
E7-01-13-25 - Outdoor Unit Fan Motor M1F Error
18
E7-02-14-26 - Outdoor Unit Fan Motor M2F Error
19
E7-05-17-29 - Outdoor Unit Fan Motor M1F
19
Overcurrent Error
19
E7-06-18-30 - Outdoor Unit Fan Motor M2F
19
E7-09-21-33 - Fan Inverter PCB A4P
19
Power Module) Overheated
19
E7-10-22-34 - Fan Inverter PCB A7P (Integrated Power Module) Overheated
20
E9-01-05-08 - Expansion Valve Y1E Abnormality
20
E9-03-06-09 - Expansion Valve Y2E Abnormality
21
E9-04-07-10 - Expansion Valve Y3E Abnormality
21
E9-20-21-22 - Failure Detection on Y1E
22
E9-23-24-25 - Failure Detection on Y2E
22
E9-26-27-28 - Expansion Valve Y4E Abnormality
23
E9-48-49-50 - Expansion Valve Overcurrent Error
23
E9-51-52-53 - Expansion Valve Thermal Cutting Error
24
E9-54-55-56 - Expansion Valve Defective Circuit
24
F3-01-03-05 - Compressor Discharge Temperature too High
25
F3-20-21-22 - Compressor Body Temperature too High
25
F4-01 - Wet Operation Caution
26
F6-02 - Refrigerant Overcharge Detection During Test-Run
26
A3P
27
A6P
27
H9-01-02-03 - Ambient Temperature Thermistor R1T Abnormality
27
Defrost Fail Alarm
28
J3-16-22-28 - Discharge Thermistor R21T Open Circuit
28
J3-17-23-29 - Discharge Thermistor R21T Short Circuit
28
J3-18-24-30 - Discharge Thermistor R22T Open Circuit
28
J3-19-25-31 - Discharge Thermistor R22T Short Circuit
29
J3-38-42-44 - Compressor Body Thermistor R9T Open Circuit
29
J3-39-43-45 - Compressor Body Thermistor R9T Short Circuit
29
J3-47-49-51 - Compressor Body Thermistor R8T Open Circuit
30
J3-48-50-52 - Compressor Body Thermistor R8T Short Circuit
30
J3-56-57-58 - High Discharge Temperature
30
J3-59-60-61 - Discharge Thermistor Crosswired
31
J5-01-03-05 - Suction Thermistor R3T Abnormality
31
J6-01-02-03 - De-Icer Thermistor R7T Abnormality
31
J7-06-07-08 - Liquid Thermistor R5T Abnormality
32
J8-01-02-03 - Outdoor Heat Exchanger Thermistor R4T Abnormality
32
J9-01-02-03 - Gas Thermistor R6T Abnormality
32
JA-06-08-10 - High Pressure Sensor S1NPH Abnormality
32
JA-07-09-11 - High Pressure Sensor S1NPH Malfunction
33
JC-06-08-10 - Low Pressure Sensor S1NPL Abnormality
33
JC-07-09-11 - Low Pressure Sensor S1NPL Abnormality
33
L1-01-07-11 - Inverter PCB A3P Abnormality
34
L1-02-08-12 - Inverter PCB A3P Current Detection Primary Circuit
34
L1-03-09-13 - Inverter PCB A3P Current Detection Secondary Circuit
34
L1-04-10-14 - Power Transistor Error on Inverter PCB A3P
35
L1-05-15-16 - Inverter PCB A3P Hardware Fault
35
L1-17-22-42 - Inverter PCB A6P Abnormality
36
L1-18-23-43 - Inverter PCB A6P Current Detection Primary Circuit
36
L1-19-24-44 - Inverter PCB A6P Current Detection Secondary Circuit
36
L1-20-25-45 - Power Transistor Error on Inverter PCB A6P
37
L1-21-26-46 - Inverter PCB A6P Hardware Fault
37
L1-28-32-34 - Fan Inverter PCB A4P Eeprom Error
37
L1-29-33-35 - Fan Inverter PCB A7P Eeprom Error
38
L1-36-38-40 - Inverter PCB A3P Eeprom Error
38
L1-37-39-41 - Inverter PCB A6P Eeprom Error
38
L1-47-49-51 - Inverter PCB A3P 16 V DC Abnormal
39
L1-48-50-52 - Inverter PCB A6P 16 V DC Abnormal
39
L2-01-02-03 - Power Supply Abnormality During Test Run
39
L2-04-05-06 - Power Supply Abnormality During Normal Operation
40
L4-01-02-03 - Inverter PCB A3P High Fin Temperature
40
L4-06-18-20 - Fan Inverter PCB A4P High Fin Temperature
40
L4-07-19-21 - Fan Inverter PCB A7P High Fin Temperature
41
L4-09-10-11 - Inverter PCB A6P High Fin Temperature
41
L5-03-05-07 - Output Overcurrent Detection on Inverter PCB A3P
42
L5-14-15-16 - Output Overcurrent Detection on Inverter PCB A6P
42
L8-03-06-07 - Overcurrent on Inverter PCB A3P Except Start-Up
42
L8-11-12-13 - Overcurrent on Inverter PCB A6P Except Start-Up
43
L9-01-05-06 - Stall Prevention by Inverter PCB A3P
43
L9-10-11-12 - Stall Prevention by Inverter PCB A6P
44
L9-13-14-15 - Inverter PCB A3P Output Phase Abnormality
44
L9-16-17-18 - Inverter PCB A6P Output Phase
44
Transmission Abnormality
45
LC-14-15-16 - Transmission Abnormality Main PCB
45
LC-19-20-21 - Transmission Abnormality Main PCB
45
LC-24-25-26 - Transmission Abnormality Main PCB
46
LC-30-31-32 - Transmission Abnormality Main PCB
46
P1-01-02-03 - Open Phase or Unbalanced Power Supply Detection by Inverter PCB A3P
47
P1-07-08-09 - Open Phase or Unbalanced Power Supply Detection by Inverter PCB A6P
47
P2-00 - Refrigerant Auto-Charge Interrupted
47
P4-01-04-05 - Fin Thermistor Abnormality on Inverter PCB A3P
48
P4-02-15-17 - Fin Thermistor Abnormality on Fan Inverter PCB A4P
48
P4-03-16-18 - Fin Thermistor Abnormality on Fan Inverter PCB A7P
48
P4-06-07-08 - Fin Thermistor Abnormality on Inverter PCB A6P
49
P8-00 - Freeze-Up During Refrigerant Auto-Charge
49
P9-00 - Refrigerant Auto-Charge Finished Normally
49
No Refrigerant in Refrigerant Cylinder During Auto-Charge
50
Refrigerant Auto-Charge in Last Stage
50
2.3.104 PF-00 - Long Test Run Failed
50
PJ-04-05-06 - Capacity Setting Mismatch for Inverter PCB A3P
50
PJ-09-15-16 - Capacity Setting Mismatch for Fan Inverter PCB A4P
50
PJ-10-17-18 - Capacity Setting Mismatch for Fan
51
Inverter PCB A7P
51
PJ-12-13-14 - Capacity Setting Mismatch for Inverter
51
Pcb A6P
51
2.3.109 U0-05 - Refrigerant Shortage Detection
51
2.3.110 U0-06 - Refrigerant Shortage Detection
52
U0-08-09-10 - Refrigerant Shortage Detection by High Pressure Sensor
52
2.3.112 U1-01-05-07 - Reverse Phase Detection
53
2.3.113 U1-04-06-08 - Reverse Phase Detection
53
U2-01-08-11 - Inverter Circuit Power Supply Abnormality - Inverter PCB A3P Abnormal Voltage
53
U2-02-09-12 - Inverter Circuit Power Supply Abnormality - Inverter PCB A3P Phase Loss
54
U2-03-10-13 - Inverter Circuit Power Supply Abnormality - Inverter PCB A3P DC Circuit Not Charging
54
U2-22-25-28 - Inverter Circuit Power Supply Abnormality - Inverter PCB A6P Abnormal Voltage
55
U2-23-26-29 - Inverter Circuit Power Supply Abnormality - Inverter PCB A6P Phase Loss
55
U2-24-27-30 - Inverter Circuit Power Supply Abnormality - Inverter PCB A6P DC Circuit Not Charging
56
2.3.120 U3-02 - Test Run Interrupted Manually
56
2.3.121 U3-03 - Test Run Not Performed yet
57
2.3.122 U3-04 - Test Run Ended Abnormally
57
U3-05 - Test Run Aborted on Initial Transmission
57
U3-06 - Test Run Aborted on Normal Transmission
57
U3-07 - Transmission Abnormality on Test Run
58
U3-08 - Transmission Abnormality on Test Run
58
U4-01 - Communication Error on
58
Transmission Line
58
U4-03 - Communication Error on F1-F2 Transmission Line
58
U4-15 - Unable to Start Test Run
59
U7-01 - Transmission Abnormality between Systems - DTA104A61,62 Error
59
U7-02 - Transmission Abnormality between Systems - DTA104A61,62 Error
59
U7-03 - Transmission Abnormality between Main
60
Outdoor Unit and Sub 1 Outdoor Unit
60
U7-04 - Transmission Abnormality between Main
60
Outdoor Unit and Sub 2 Outdoor Unit
60
2.3.134 U7-05 - Multi System Abnormality
60
2.3.135 U7-06 - Multi System Address Abnormality
61
U7-07 - more than 3 Outdoor Units on Q1-Q2 Transmission
61
U7-11 - Excess Indoor Units Detected on Test Run
61
U7-24 - Duplication of Address Setting on Multiple DTA104A61,62 Installation
61
2.3.139 U9-01 - Other Indoor Unit Has Error
61
2.3.140 UA-00 - Combination Abnormality
62
Combination Abnormality - MIX of R22, R407C and R410A Type Units Detected
62
Combination Abnormality - more than 64 Indoor Units Detected on same System
62
Combination Abnormality - Local Setting Abnormality
62
Combination Abnormality - Outdoor Unit Not Compatible with Indoor Units (Refrigerant Type)
63
Combination Abnormality - Local Set Alarm
63
Combination Abnormality - Non-Compatible Outdoor Unit in Multi-Combination
63
Combination Abnormality - BPMK Units Detected
63
Combination Abnormality - Multi Combination Abnormality
63
Combination Abnormality - Altherma Hydro Unit Detected
64
Combination Abnormality - Incorrect Combination
64
Combination Abnormality - Wrong Unit Combination
64
Wiring and Piping Mismatch - Auto Address
64
Inconsistency on F1-F2 Transmission
64
Wiring and Piping Mismatch - Stop Valves Closed or Incorrect
64
Wiring and Piping Mismatch - Excess Connection Ratio
65
2.3.155 UH-01-02 - Auto-Address Failure
65
Refrigerant Leak Check Is Not Possible
65
Refrigerant Leak Check Cannot be Performed - Indoor Air Temperature Is out of Range
66
Refrigerant Leak Check Cannot be Performed - Outdoor Air Temperature Is out of Range
66
Refrigerant Leak Check Is Interrupted - too Low Pressure Is Detected
66
Refrigerant Leak Check Cannot be Performed - a Unit Which Is Not Compatible with Leak Detection Function Is Installed
66
NG - Refrigerant Leak Check Function Detects Refrigerant Leak
66
OK - Refrigerant Leak Check Function Detects no Refrigerant Leak
67
2.3.163 Indoor Unit Related Error Codes
68
2.3.164 Overview of Error Codes
69
Symptom Based Troubleshooting
73
Normal Operating Conditions
73
Symptom: the System Does Not Operate
73
Symptom: Cool/Heat Cannot be Changed over
73
Symptom: Fan Operation Is Possible, but Cooling and Heating Do Not Work
73
Symptom: the Fan Speed Does Not Correspond to the Setting
73
Symptom: the Fan Direction Does Not Correspond to the Setting
73
Symptom: White Mist Comes out of a Unit (Indoor Unit)
73
Symptom: White Mist Comes out of a Unit (Indoor Unit, Heat Exchanger Unit)
73
Symptom: the User Interface Display Reads "U4" or "U5" and Stops, but then Restarts after a few Minutes
73
Symptom: Noise of Air Conditioners (Indoor Unit, Outdoor Unit)
74
Symptom: Noise of Air Conditioners (Outdoor Unit)
74
Symptom: Dust Comes out of the Unit
74
Symptom: the Units Can Give off Odours
74
Symptom: the Outdoor Unit Fan Does Not Spin
74
Symptom: the Display Shows "88
74
Symptom: the Compressor in the Outdoor Unit Does Not Stop after a Short Heating Operation
74
Symptom: the Inside of an Outdoor Unit Is Warm Even When the Unit Has Stopped
74
Symptom: Hot Air Can be Felt When the Indoor Unit Is Stopped
74
Symptom: Unit Operation Problems
75
Other Symptoms
76
Components
77
4-Way Valve
77
Main 4-Way Valve
77
Sub 4-Way Valve
80
Compressor
82
Checking Procedures
82
Repair Procedures
84
Crankcase Heater
87
Checking Procedures
87
Repair Procedures
87
Current Sensor
88
Checking Procedures
88
Repair Procedures
88
Expansion Valve
89
Checking Procedures
89
Repair Procedures
90
Fan Inverter PCB
92
Single Fan Outdoor Unit
92
Double Fan Outdoor Unit
95
High Pressure Switch
97
Checking Procedures
97
Repair Procedures
98
Inverter PCB
99
Checking Procedures
99
Repair Procedures
103
Main PCB
106
Checking Procedures
106
Repair Procedures
108
Noise Filter PCB
110
Checking Procedures
110
Repair Procedures
112
Oil Return Valve
112
Checking Procedures
112
Repair Procedures
114
Outdoor Unit Fan Motor
115
Single Fan Outdoor Unit
115
Double Fan Outdoor Unit
116
Plate Work
118
To Access the Switch Box on Single Fan Units
118
To Access the Switch Box on Double Fan Units
119
To Remove the Plate Work on Single Fan Units
119
To Remove the Plate Work on Double Fan Units
121
Reactor
123
Checking Procedures
123
Repair Procedures
124
Refrigerant High Pressure Sensor
124
Checking Procedures
124
Repair Procedures
125
Refrigerant Low Pressure Sensor
126
Checking Procedures
126
Repair Procedures
127
Thermistors
128
Refrigerant Side Thermistors
128
Other Thermistors
130
Third Party Components
130
Electrical Circuit
130
Checking Procedures
130
Repair Procedures
133
Refrigerant Circuit
133
Checking Procedures
133
Repair Procedures
136
External Factors
138
Checking Procedures
138
Repair Procedures
139
Maintenance
140
Maintenance Shedule
140
Maintenance Procedures for Outdoor Units
140
To Check the General Status of the Unit
140
To Clean the Cover Plates
140
To Clean the Outdoor Unit Heat Exchanger
141
Maintenance Procedures for Indoor Units
142
To Check the General Status of the Unit
142
To Clean the Cover Plates
142
To Clean the Indoor Unit Heat Exchanger
142
Direct Expansion: Maintenance - VRV
143
Technical Data
145
Detailed Information Setting Mode
145
Detailed Information Setting Mode: Outdoor Unit
145
Detailed Information Setting Mode: Remote Controller
145
Wiring Diagram
146
Wiring Diagram: Outdoor Unit
146
Piping Diagram
148
Piping Diagram: Outdoor Unit
148
Refrigerant Flow Diagram: Outdoor Unit
151
Component Overview
164
Component Overview: RXYQ8~12U Units
164
Component Overview: RXYQ14~16U Units
166
Component Overview: RXYQ18~20U Units
168
Component Overview: RYMQ8~12U Units
170
Component Overview: RYMQ14~16U Units
172
Component Overview: RYMQ18~20U Units
174
Component Overview: RYYQ8~12U Units
176
Component Overview: RYYQ14~16U Units
178
Component Overview: RYYQ18~20U Units
180
Switchbox Overview
182
Single Fan Units
182
Double Fan Units
182
Safety Devices
183
Field Information Report
184
Service Tools
187
Field Settings
188
To Access Mode 1 or 2
188
To Use Mode 1
188
To Use Mode 2
188
Mode 1: Field Settings
189
Mode 2: Field Settings
191
Overview of Field Settings for Indoor Units
194
Field Settings as Per Type of Indoor Unit
197
Other manuals for Daikin RXYQ8U7Y1B
Installation And Operation Manual
52 pages
4
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the Daikin RXYQ8U7Y1B and is the answer not in the manual?
Ask a question
Daikin RXYQ8U7Y1B Specifications
General
Model
RXYQ8U7Y1B
Category
Heat Pump
Cooling Capacity
8.0 kW
Refrigerant
R-32
Power Supply
50Hz
Noise Level (Outdoor Unit)
56 dB
Related product manuals
Daikin RXYQ8PY1
355 pages
Daikin VRV RXYQ8P7W1B
139 pages
Daikin VRV II RXYQ8MY1K
310 pages
Daikin VRV II RXYQ8MY1B
344 pages
Daikin RXYQ18PY1
355 pages
Daikin RXYQ16PY1
355 pages
Daikin RXYQ96PTJU
20 pages
Daikin RXYQ144PTJU
20 pages
Daikin RXYQ12U7Y1B
52 pages
Daikin RXYQ10U7Y1B
52 pages
Daikin RXYQ96TATJU
337 pages
Daikin RXYQ16U7Y1B
52 pages