SiE39-404
Ser vice
Manual
R-410A Heat Pump 50Hz

Table of Contents

Other manuals for Daikin VRV II RXYQ16MY1B

Question and Answer IconNeed help?

Do you have a question about the Daikin VRV II RXYQ16MY1B and is the answer not in the manual?

Daikin VRV II RXYQ16MY1B Specifications

General IconGeneral
ModelRXYQ16MY1B
Cooling Capacity45.0 kW
Heating Capacity50.0 kW
RefrigerantR410A
Operating Temperature (Cooling)-5°C to 46°C
Sound Pressure Level (Outdoor Unit)62 dB(A)
TypeHeat Pump
Power Supply380-415V, 50Hz, 3 Phase
Compressor TypeScroll
Operating Temperature (Heating)-20°C to 15.5°C

Summary

Service Manual Daikin VRV II R-410A Heat Pump 50Hz

Part 1 General Information

Model Names of Indoor and Outdoor Units

Lists model names and capacities for various indoor and outdoor units.

Part 2 Specifications

Specifications of Outdoor Units

Details technical specifications like cooling capacity, dimensions, and components.

Part 3 Refrigerant Circuit

Refrigerant Circuit Diagrams

Provides schematic diagrams of the refrigerant circuit for different outdoor unit models.

Refrigerant Flow for Each Operation Mode

Explains the refrigerant flow path during cooling, oil return, and heating operations.

Part 4 Function

Protection Control Functions

Explains high pressure, low pressure, discharge pipe, inverter, and compressor overload protections.

Part 5 Test Operation

Test Operation Procedures

Outlines pre-checks, power-on procedures, and check operation steps for installation.

Part 6 Troubleshooting

Troubleshooting using Remote Controller

Explains how to use inspection/test buttons, service modes, and self-diagnosis functions.

Troubleshooting based on Remote Controller Error Codes

Lists indoor and outdoor unit error codes, their causes, and suggested countermeasures.

Troubleshooting Central Remote Controller Issues

Troubleshooting UE: Central Remote to Indoor Unit Transmission Malfunction

Details steps to diagnose and resolve transmission errors between central controllers and indoor units.

Troubleshooting Schedule Timer Issues

Troubleshooting UE: Schedule Timer to Indoor Unit Transmission Malfunction

Details how to diagnose and fix transmission errors between the schedule timer and indoor units.

Part 7 INV Compressor Replacement Procedure

INV Compressor Replacement Procedure for VRV II

Provides detailed steps for replacing the INV compressor in VRV II units (RXYQ5M to 48M).

Part 8 Appendix

Pipe Size, Joints, and Header Selection

Guides on selecting appropriate pipe sizes, joints, and headers based on system capacity.

Replacing Inverter Power Transistors and Diode Modules

Explains the procedure for replacing power transistors and diode modules on the inverter PC board.

Part 9 Precautions for New Refrigerant (R410)

Precautions for R410A Refrigerant

Covers characteristics, pressure, composition, and handling of R410A refrigerant.

Related product manuals