English 16
The main menu has the following items.
Menu item Description
Reference page
Air Flow Direction
Used to congure air ow direction settings.
The air ow direction louver is automatically operated up and down (left and right).
The xed air ow directions are congurable for ve positions.
* This function is not available on all models.
17
Ventilation
Ventilation
operation settings
for energy
recovery
ventilator
Ventilation Rate
Used to set “Low” or “High”
18
Ventilation Mode
Used to set Auto, ERV, or Bypass.
19
Schedule Daily Patterns
Day settings are selected from three patterns, i.e., “7Days”, “Weekday/
Weekend”, and “Weekday/Sat/Sun”.
20
Settings
Set the startup time and operation stop time.
ON:  Startup time, cooling and heating temperature setpoints can be congured.
OFF: Operation stop time, cooling and heating setback temperature setpoints
can be congured. 
(
--
: Indicates that the setback function is disabled for this time period. )
_
: Indicates that the temperature setpoint and setback temperature setpoint
for this time period is not specied. The last active setpoint will be utilized.
Up to ve actions can be set for each day.
21
O󰀨 Timer
Used to set each operation period of the system.
Possible to set in 10 minute increments from 30 to 180 minutes.
23
Celsius / Fahrenheit
Used to select whether temperature values will be displayed in Celsius or
Fahrenheit.
Maintenance Information
Used to display the maintenance information.
24
Conguration
Contrast
Adjustment
Used to make LCD contrast adjustment.
25
Display
Standard or Detailed
Display
Used to set standard or detailed display mode.
Display mode
Standard or detailed display
Detailed display provides the choice to display between Room Temp, Outside Air
Temp, System or None.
25
Current Settings
Used to display a list of current settings for available items.
26
Clock &
Calendar
Date & time
Used to congure date and time settings and corrections.
The default time display is 12H.
The clock will maintain accuracy to within ±30 seconds per month.
If there is a power failure for a period not exceeding 48 hours, the clock will
continue working with the built-in backup power supply.
27
12H/24H Clock
The time can be displayed in either a 12 hour or 24 hour time format.
28
Daylight Saving Time
Used to adjust the clock in observance of daylight saving time.
Language
The display language can be selected between English, Francais, Espanol.
29
Note: Available setting items vary with the indoor unit model.
Sub Remote Controller Menu Items
Two remote
controllers in control
Outside unit
Indoor unit
If two remote controllers are in control of a single indoor unit, the following menu items are not set in
the sub remote controller. In this case, the following items should be congured in the main remote 
controller.
Schedule
O󰀨 timer
Setback
Quick Reference