English 8
1. Operation mode
Used to display the current operation
mode: Cool, Heat, Vent, Fan, Dry or Auto.
2. Fan Speed
Used to display the fan speed that is set for the indoor unit.
The fan speed will not be displayed if the connected model does
not have fan speed control functionality.
3. Setpoint display
Used to display the setpoint for the indoor unit.
Use the Celsius/Fahrenheit item in the main menu to select the
temperature unit (Celsius or Fahrenheit).
4. Stand by for Hot start
STANDBY
(See page 10.)
If ventilation icon is displayed in this eld:
Indicates that an energy recovery ventilator is connected.
For details, refer to the Operation Manual of the ERV.
5. Message
The following messages may be displayed.
“This function is not available”
Displayed for a few seconds when an operation button is
pressed and the indoor unit does not provide the corresponding
function.
In a remote control group, the message will not appear if at least
one of the indoor units provides the corresponding function.
“Error: Push Menu button”
“Warning: Push Menu button”
Displayed if an error or warning is detected (see page 30).
“Time to clean lter”
“Time to clean element”
“Time to clean lter & element”
Displayed as a reminder when it is time to clean the lter or 
element (see page 29).
6. Ventilation
Displayed when a energy recovery ventilator is connected.
Ventilation Mode icon.“
AUTO
ERV
ERV
BYPASS
These icons indicate the current ventilation mode (ERV only)
(AUTO, ERV, BYPASS).
Air Purify ICON “
AIR
PURIFY
This icon indicates that the air purifying unit (option) in
operation.
7. display (See page 14.)
Displayed when the key lock is set.
8. display (See page 19.)
Displayed if the Schedule or O󰀨 timer is enabled.
9. Under Centralized control “
Displayed if the system is under the management of a multi-
zone controller (option) and the operation of the system through
the remote controller is limited.
10. Changeover controlled by the master indoor
unit “
MASTER
CONTROLLED
Displayed when another indoor unit on the system has the
authority to change the operation mode between cool and heat.
11. Setback “
SETBACK
(See page 11.)
The setback icon ashes when the unit is turned on under the 
setback control.
12. Air Flow Direction “
Displayed when the air ow direction and swing are set (see
page 17).
If the connected indoor unit model does not include oscillating
louvers this item will not be displayed.
13. Current Day/Time (12/24 hour time display)
Displayed if the clock is set (see page 27).
If the clock is not set, “ -- : -- ” will be displayed.
12 hour time format is displayed by default.
Select 12/24 hour time display option in the main menu under
“Clock & Calendar”.
14. Detailed selection
Displayed if the detailed display item is selected (see page 26).
Detailed items are not selected by default.
15. display
Displayed when the clock needs to be set.
The schedule function will not work unless the clock is set.