44
13. Technical data
Technical specifications Control panel SH320AU SH340AU SH380AU
Power supply BatLi 22 lithium power pack: 2 x (3.6 V 13 Ah)
or 200-240 VAC 50-60 Hz / 4.5 VDC 2.2 A mains power module backed up by Li-Ion 3.7 V
1.2 Ah battery (not supplied)
Battery life 5 years in normal conditions of use
Average current consumed 335 µA
Average humidity rate from 5% to 75% without condensation at 25°C
Radio link TwinBand
®
, 400/800 MHz
Control panel specifications • SH320AU: 2 separate groups
SH340AU: 4 separate groups
SH380AU: 8 separate groups
progressive deterrence
personnel protection
15 remote control units maximum
SH320AU: 20 intrusion detectors maximum
SH340AU: 40 intrusion detectors maximum
SH380AU: 80 intrusion detectors maximum
10 deterrence devices maximum
32 user codes
5 radio repeater relays maximum
3 diallers maximum (transmission module included)
vocal personalisation of detectors (40 max)
system saved to S.I.T.E. NVM stick (optional)
built-in command keypad
built-in remote control operation (if transmission module installed)
log of last 1,000 date and time-stamped events
2 hardwired outputs + 1 hardwired input (optional)
Operating temperature - 10 °C to + 55 °C
Degrees of mechanical protection IP 31 / IK 04
Environment
indoors
degree of pollution: 2
category of overpressure: II
maximum altitude: 2 000 meters
Tamper protection against opening
against removal
against line cuts (if transmission module installed)
against attempts to discover radio codes
against radio interference
Supervision radio
lithium power pack BatLi22 / 230 VAC mains power module / battery Li-Ion
tamper
Siren acoustic power 108 dB(A) at 1 m
Audible alarm built-in
Dimensions 232 x 232 x 67,7 mm
Weight (without battery) 1 200 g
Security grade grade II according to EN 50131-3
Environmental class class II according to EN 50130-5
Description of symbols
The product is in conformity with the fundamental obligations as regards safety, of hygiene and environmental protection.
Risk of electric
shock
Risk of electric shock.
Li
In order to avoid harming the environment and human health, you should not dispose of this product with normal household
waste, do not not place in a waste bin with household waste. It must be given to a point of collection suitable for the
categorisation, treatment, and recycling. The lithium power supplies contain substances which can pollute the environment.
They must be given to an approved recycling centre.
The power supply MUST be labelled with this symbol of double insulation, for a 230 VAC supply without ground connection.
For indoor use only.
!
The note must absolutely be consulted before installation, use and maintenance of the equipment.