6
Compartment for input/output card (optional)
CAUTION: the system is sold without
S.I.T.E. module, it is an option and
allows:
• the storing of the parameters of all
the products of the system,
• the storing of the recorded vocal
messages.
IMPORTANT: connection and the
disconnection of the S.I.T.E module
must.
ONLY be done when the Control
panel is UNPOWERED !
Tamper pin
Base
Slot for cable
clamp supplied in
bag of accessories
Compartment:
- lithium power pack
or
- internal mains power module
(not supplied)
Compartment
for Li-Ion rechargeable
back-up battery
(optional)
Compartment for
S.I.T.E. NVM stick
(optional and not
compulsory)
Detachable washer
Inside view
Rear view
1 x 2-point connector
for rechargeable
back-up battery
Do not connect the 230 V
mains to relay outputs.
{
}
LED indications
LEDs LED status Meaning
Three-colour LED
red
steady button pressed or line occupied
continuous rapid flashing operation blocked when powered
12 s maximum rapid flashing connection test, date and reference
1 flash every 5 s permanent indication of test mode
2 flashes every 10 s permanent indication of installation mode
3 rapid flashes error
green
steady for 10 seconds valid access code
steady recording of 10 s maximum voice message
orange
rapid flashing during message saving (1) (no other vocal personalisation possible)
1 flash every 20 s
system fault (power fault, media fault (2) or loss of product radio link)
in user mode and when system is disarmed
Blue light
modulated indication
mode change: installation, test and use
arming or disarming
system status command
one of the 4 customisable keys pressed (arm, disarm, arm partial 1 and 2)
(1) If SITE NVM stick or transmission module installed.