Air Conditioner Service Manual
39
Cooling system gas flow abnormal
PROTECTION..
Please check the troubleshooting for detail.
Please check the troubleshooting for detail.
The Compressor lack of phase / Anti-phase
PROTECTION.
Please check the troubleshooting for detail.
IPM Module temperature PROTECTION
Please check the troubleshooting for detail.
4-Way Value reversing abnormal..
Please check the troubleshooting for detail.
The module temperature test circuit failure.
The compressor Phase-current test circuit
failure.
Limiting/Reducing frequency for Over load
protection on Cooling/Heating mode.
Querying by press remote controller
Limiting/Reducing frequency for High power
consumption protection.
Querying by press remote controller
Limiting/Reducing frequency for Module
current protection ( phase current of
compressor).
Querying by press remote controller
Limiting/Reducing frequency for Module
temperature protection.
Querying by press remote controller
Limiting/Reducing frequency for Compressor
driving protection.
Querying by press remote controller
Limiting/Reducing frequency for anti-
condensation protection..
Querying by press remote controller
Limiting/Reducing frequency for anti-frost
protection.
Querying by press remote controller
Limiting/Reducing frequency for Discharge
over temperature protection.
Querying by press remote controller
Limiting/Reducing frequency for ODU AC
Current protection.
Querying by press remote controller
Please check the troubleshooting for detail.
TVOC sensor failure(IDU failure, optional)
Querying by press remote controller
PM2.5 sensor failure(IDU failure, optional)
Querying by press remote controller
Humidity sensor failure. (IDU failure)
Querying by press remote controller
Note: Remote controller FAILURE CODE Querying function
As shown in the failure codes, some of the codes (Fb~bj) need to press remote control for inspection.
While unit on operation, press the ECO button 8 times with 8 seconds, the buzzer BIBI 2 times, you can inspect
the special failure code as Fb ~Fn, bj etc.