EasyManua.ls Logo

Dalla Corte DC PRO XT - Page 110

Dalla Corte DC PRO XT
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
110 |
Alarm Cause Effect
Level
timeout
This alarm is triggered when
the autofill function fails to bring
the water in the boiler to the
pre-established level within
the time set in the programming
Autofill function is blocked; tap DEL
on the display to cancel the alarm
and restart the autofill
Safety
level
This alarm is triggered when
the water level in the boiler
drops below the safety sensor's
threshold
Boiler heating is blocked; tap DEL
on the display to cancel the alarm.
If the alarm repeats, contact an authorized
technical service provider
Grinder
service
failure
This alarm is triggered when
the espresso machine
and the grinder connected
to are unable to communicate
with each other (GCS function)
Grinder auto-regulation blocked; tap DEL
on the display to cancel the alarm.
If the alarm repeats, contact an authorized
technical service provider and temporarily
use the continuous dispensing button
Cashier
serial
port
failure
This alarm is triggered when
the coffee machine and the cashier
connected to it are unable
to communicate with each other
All brewing is blocked; tap DEL
on the display to cancel the alarm.
If the alarm repeats, contact an authorized
technical service provider

Table of Contents

Related product manuals