Serie "LXS9"
Page 19
Rev. M - 01
- CHECK OF PRODUCT DOOR MICROSWITCHES AND MAGNETS ()
Product removal door (4) operation can be checked by performing the door closing and
opening test (see: programm.-> diagnostics ->Product door test). If necessary, it is possible
to remove the magnet covering panel on the lower internal part of the door to inspect the
microswitches (6) that lock the product door (4) and the closing magnets (5), in particular to
check the condition of the levers of the microswitches and that the magnets can move freely.
After having reassembled the magnet covering panel, perform a door closing and opening
test (see: programm.-> diagnostics ->Product door test)
- CHECK/CLEANING OF THE REFRIGERATION UNIT CONDENSER ()
Turn the vending machine off using the main switch, access the refrigeration unit as
described in the “refrigeration unit disassembly and reassembly” chapter, inspect the
condenser and clean it if necessary, removing any residues with a brush or
suctioning/blowing air. Make sure that dust is not raised during these operations; turn the
vending machine back on only after having replaced the refrigeration unit in its normal work