EasyManuals Logo

damian LXS9 Series User Manual

damian LXS9 Series
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #36 background imageLoading...
Page #36 background image
Serie "LXS9"
Pagina A - 14
Rev. M - 01
> NIGHT MODE INTERNAL TEMPERATURE SETTING:
(Visible and programmable only with Vivilight Kit installed and “Refrigerator operation” other than “Food & Snack”)
This parameter allows setting the internal temperature of the vending machine when the Night Mode
function is activated. Settable values: 0 ÷ 50°C.
The refrigerator temperature raising function is deactivated during the Night-Mode period if the parameter
is set to 0‟ (Zero) or to a value below the one set as standard internal temperature („Set Std Temp 1‟ in the
Refrig. Param‟s” menu).
This parameter can also be programmed through the Energy Saving menu in the General Param‟s”.
Refer to the “Energy Saving” section for further information on this function.
[ Default: 0°C ]
> REFRIGERATION UNIT WORKING TEMPERATURE READING:
(Only visible if 2
nd
refrigerator probe present)
To read the working temperature inside the refrigeration unit evaporator.
[ Read only ]
> SAFETY TEMPERATURE:
(Visible and programmable only with „Refrigerator operation = Food & Snack‟)
To read the safety temperature for the sale of food products; see the Overtemperature control section
and the description of the “ERR L09” error message for the description.
Settable values: 0 ÷ 45°C.
To deactivate this function, set it to 40°C.
[ Default: 45 °C ]
> OVERTEMPERATURE TIME:
(Visible and programmable only with „Refrigerator operation = Food & Snack‟)
To set the time beyond which the internal temperature must not exceed the safety temperature; see the
Overtemperature control section and the description of the ERR L09 message for the description.
Settable values: 0 ÷ 1440 minutes.
[ Default: 30 minutes]
> RESTOCKING TIME:
(Visible and programmable only with „Refrigerator operation = Food & Snack‟)
To set the time that is added to the overtemperature time each time restocking takes place (vending
machine turned on); see the Overtemperature control section for the description. Settable values: 0 ÷
1000 minutes.
[Default: 120 minutes]
> CONNECTED PROBES:
To read the number of refrigeration unit control probes that are connected.
[ Read only ]
Programming
Refrig. Param's
Night Mode temp.
Current value
F
Programming
Refrig. Param's
Probe 2 measure
Current value
F
Programming
Refrig. Param's
Security temper.
Current value
F
Programming
Refrig. Param's
Overtemper. time
Current value
F
Programming
Refrig. Param's
Refueling time
Current value
F
Programming
Refrig. Param's
Connected probes
Current value
F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the damian LXS9 Series and is the answer not in the manual?

damian LXS9 Series Specifications

General IconGeneral
Branddamian
ModelLXS9 Series
CategoryVending machines
LanguageEnglish

Related product manuals