List of supported parameters:
par
Name
Definition
Range
Standard
001
Loco address unit position
0 – 99
1
002
Loco address hundred position
0 – 99
10
003
Loco address for SX1
If > 111 deactivated
0 – 255
112
004
Additional channel 1 for SX1
Functions F1 – F8
0 – 255
1
005
Additional channel 2 for SX1
Functions F9 – F16
0 – 255
0
006
Loco address output
Activated = 1
0, 1
1
007
Effectiveness additional channels
0 = relative:
Additional 1 = par003 + par004
Additional 2 = par003 + par005
1 = absolute
0, 1
0
008
Consist address unit position
Reserved
009
Consist address hundred position
Reserved
011
Acceleration time
The value corresponds to the time
in seconds from start to maximum
speed
0 – 255
3
012
Deceleration time
See par011
0 – 255
3
013
Maximum speed
See supplement 2
0 – 127
92
014
Starting voltage
Minimum speed
0 – 15
0
016
Start delay speed step 1
Each 0,1 sec
Delay between receive of speed
step 1 and start for the SUSI
interface
0 – 250
0
018
Shunting gear speed
See supplement 2
0 – 127
63
019
Shunting gear deceleration
See par011
0 – 255
1