4
Speci cation
Power Supply 230Vac, ± 15%, 50 Hz
Switching Action 1 x SPST, Type 1B
Switch Rating 264Vac, 50/60Hz, 3(1)A
Setting/Running Accuracy ±1 min./month
Power Reserve Minimum 24 hours
Max. Ambient Temperature 45°C
Dimensions, mm (W, H, D) 102 x 136 x 47
Design Standard EN 60730-2-7
Control Pollution Situation Degree 2
Rated Impulse Voltage 2.5kV
Ball Pressure Test 75°C
NB. For FRU units - go straight to point 6.
1. Loosen the  xing screw in the base of the unit to release the
Wiring Cover.
2. Holding the unit face downwards, press  rmly in the centre of
the wallplate and slide it apart and lift it from the module.
1.0 Installation Overview
2.0 Product Speci cation
Please Note:
This product should only be installed by a quali ed electrician or
competent heating installer and should be in accordance with the
current edition of the IEEE wiring regulations.
3.0 Installation

Other manuals for Danfoss 103E7