EasyManuals Logo
Home>Danfoss>Water Pump>APP 0.6

Danfoss APP 0.6 Disassembling And Assembling Instructions

Danfoss APP 0.6
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
Service guide | Disassembling and Assembling, APP 1.5-3.5
© Danfoss | DCS (im) | 2017.084 | 180R9091 | DKCFN.PI.013.EF5.02 | 521B0741
8. Remove the port plate.
10. Replace the O-rings and the back-up rings
on the valve plate. Mount the new back-
up rings on the new valve plate first and
then mount the new O-rings.
Wet the O-rings and back-up rings with
clean (filtered) soap water.
9. Gently lever the valve plate assembly free
with the aid of a screwdriver.
11. Gently press, by hand, the valve onto the
cylinder barrel.
Mount backup
ring first
Then mount
O-ring
7. Remove the cylinder barrel.
12. Gently push flushing valve out using the
Allen key.