Service guide | Disassembling and Assembling, APP 1.5-3.5
© Danfoss | DCS (im) | 2017.08 180R9091| DKCFN.PI.013.EF5.02 | 521B0741| 7
2. Change of shaft seal
1. Unscrew the 4 mounting screws and
remove the seal SAE flange.
Do not unscrew the 2 recessed screw at
this time.
Tools needed
2. Wet the shaft and shaft seal with
clean (filtered) soap-water. Gently lever
the shaft seal assembly free with the aid of
2 screwdrivers.
3. Fit the hollow bush (torpedo) to the shaft.
Wet the torpedo and replacement shaft
seal with soap. Do not use silicone
grease.
Recessed
screws
Recessed
screws
4. Slide the shaft seal over the torpedo with
the carbon seal face pointing upwards. Be
careful not to damage the carbon seal
face on the shaft seal.