7
180R9267 / IOM APP 1.5-3.5 Appendices - v04 / 11.2013
Data sheet APP pumps - APP 1.5-3.5
5
521B0850 / DKCFN.PD.013.FA6.02 / 09.2012
6. Power requirements
Pump
model
Flow Pressure rpm Calc.
factor
60 bar 70 bar 80 bar
l/min m
3
/h gpm 870 psi 1015 psi 116 0 psi
APP 1.5 25.11 1.51 6.63 3.21 kW 3.75 kW 4.29 kW 2890 468.6
APP 1.5 30.17 1.81 7.97 3.86 kW 4.51 kW 5.15 kW 3470 468.6
APP 1.8 26.78 1.61 7.07 3.43 kW 4.00 kW 4.57 kW 2890 463.2
APP 1.8 32.18 1.93 8.50 4.12 kW 4.81 kW 5.49 kW 3470 463.2
APP 2.2 33.48 2.01 8.84 4.29 kW 5.00 kW 5.71 kW 2900 468.6
APP 2.2 40.22 2.41 10.63 5.15 kW 6.01 kW 6.87 kW 3480 468.6
APP 2.5 41.94 2.52 11.0 8 5.07 kW 5.92 kW 6.77 kW 2900 484.8
APP 3.0 48.2 2.9 12.7 6.2 kW 7.2 kW 8.2 kW 2930 470.0
APP 3.5 56.0 3.4 14.8 7.2 kW 8.4 kW 9.6 kW 2930 470.0
The power requirements can be determined using one of the following guiding equations:
l/min × bar 16.7 × m3/h × bar 0.26 × gpm × psi
Required power = [kW] or [kW] or [kW]
Calc. factor Calc. factor Calc. factor
1 hp = 0.75 kW
1 kW = 1.34 hp
1 gpm = 3.79 l/min
1 l/min = 0.26 gpm
1 m
3
/h = 4.40 gpm
1 gpm = 0.23 m
3
/h
7. Temperature and
corrosion
The chart below illustrates the corrosive
resistance of dierent types of stainless steel
related to NaCl concentration and temperature.
All critical parts of the APP water pump is made
of Super Duplex.
If the water pump is operated at high salinity,
always ush the water pump with fresh water at
operation stop in order to minimize the risk of
crevice corrosion.
7.1 Operation
Fluid temperature:
+2° C to +50° C (+35.6° F to 122° F) dependent on
the NaCl concentration
Ambient temperature: