3 Heat pump data, dimensions and connections
3.1 DHP-H, DHP-H Opti
110
1845 (±10)
455
596
528
300
440
40±10
1
2
610
80
4
7
8
6
5
9
3
Figure 1. Dimensions and connections
Symbol explanation
1 Brine in, 28 Cu
2 Brine out, 28 Cu
3 Heating system supply pipe, 22 Cu: 4-10 kW, 28 Cu: 12-16 kW
4 Heating system return pipe, 22 Cu: 4-10 kW, 28 Cu: 12-16 kW
5 Connection for bleed valve, 22 Cu
6 Hot water line, 22 mm
7 Cold water line, 22 mm
8 Lead-in for supply, sensor and communication cables
9 Safety valve for temperature and pressure (only applies to
certain models)
The brine pipes can be connected on either the left or right-hand sides
of the heat pump.
3.2 DHP-H Opti Pro
110
1845 (±10)
455
596
528
300
440
40±10
1
2
610
80
4
7
8
6
5
9
3
Figure 2. Dimensions and connections
Symbol explanation
1 Brine in, 28 Cu
2 Brine out, 28 Cu
3 Heating system supply pipe, 22 Cu: 4-10 kW, 28 Cu:
12-16 kW
4 Heating system return pipe, 22 Cu: 4-10 kW, 28 Cu: 12-16
kW
5 Connection for bleed valve, 22 Cu
6 Hot water line, 22 mm
7 Cold water line, 22 mm
8 Lead-in for supply, sensor and communication cables
9 Safety valve for temperature and pressure (only applies
to certain models)
The brine pipes can be connected on either the left or right-hand sides
of the heat pump.