Fluid viscosity limits
Conditions mm
2
/s (cSt) SUS
Minimum 12 66
Continuous 20 - 80 98 - 370
Maximum 1500 6950
We recommend the use of an oil type having a viscosity of 35 mm
2
/s at the actual operating temperature.
Filtering
It is necessary to keep the level of oil contamination at an acceptable level to ensure problem-free
operation. The recommended maximum level of contamination in systems with Danfoss hydraulic orbital
motors is 22/20/16 (ISO 4406-1999).
Painting of the motor
W
Warning
Danfoss ATEX certified motors are without painting. In case of additional painting of the motor please
make sure that the thickness is in accordance with the relevant standards.
User Manual
ATEX instruction for OMS, OMT and OMV
Technical information
©
Danfoss | September 2016 11160602 | AQ00000213en-US0103 | 11