Installation
Impurities
8.
Prior to installation, burrs and chips and
other impurities must be removed from
pipes and hoses, eg with a felt plug
Chips or other impurities in the system
may cause damage
Sealing
9.
Fittings in screwed components to be
sealed with O-rings or bonded seals
Using teon tape or packing yarn in
joints may cause damage
Grease
10.
Correctly limited quantities of grease
prevent seizing
Too much grease may develop
biolm causing operational failures
Water supply
13.
Fill system with water before starting
to ensure lubrication and cooling
Starting without water will cause
damage
Coupling
12.
Ensure always to have 3 mm distance
between coupling anges
Insucient distance and/or misalign-
ment between the coupling anges
will damage the pump
= min. 3 mm
0 mm
Assembly of coupling
11.
The coupling must be easy and simple
to assemble (see product instruction)
Never use force when assembling the
coupling parts, as this will damage the
motor/pump
75
180R9379 | AQ188686503004en-000801 | PAH 2-12.5 } 07.2022

Table of Contents

Other manuals for Danfoss PAH 50

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss PAH 50 and is the answer not in the manual?

Danfoss PAH 50 Specifications

General IconGeneral
BrandDanfoss
ModelPAH 50
CategoryWater Pump
LanguageEnglish

Related product manuals