EasyManua.ls Logo

Danfoss PAHT - Flow; PAHT 2-6.3 Typical Ow Curves at Max Pressure

Danfoss PAHT
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26 | 180R9288_AQ109686503100en-001301 © Danfoss | 2023.12
Operation guide Installation, Operation and Maintenance Manual for PAHT 20-90 pumps
5. Flow
The ow (Q
e
) at various pressure (p
max
) can be
calculated with the following equation:
Q
e
= Q
(th)
– [(Q
(th)
– Q (p
max
)) x (p / p
max
)]
The theoretical ow can be calculated with the
following equation:
V x n
Q
(th)
=
1000
At zero pressure the true ow equals the
theoretical ow Q
(th)
.
Q
(th)
: Theoretical ow (l/min / gpm)
Q (p
max
): Flows at max. pressure (l/min and
gpm), see 4.1-4.4
p
max
: Max pressure (barg / psig)
p: Pressure (barg / psig)
V: Displacement (cm
3
/ rev.)
n: Motor speed (rpm)
5.1 PAHT 2-6.3 typical flow curves at max pressure
20
18
16
14
12
10
8
6
4
2
0 rpm
PAHT 2.0
PAHT 3.2
PAHT 4.0
PAHT 6.3
l/min
1000
1250
1500
1750
2000
2500
2250
2750
3000
5.0
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
gpm
0
1000
1250
1500
1750
2000
2500
2250
2750
3000
rpm
PAHT 6.3
PAHT 4.0
PAHT 3.2
PAHT 2.0