6
Systems with dial thermostats continued
Operating instructions for the underfloor heating timeclocks
TS715 – Single-channel timeclock
Nu-Heat supplies Danfoss TS715 single-channel programmable floor heating
timeclocks to control the underfloor heating system.
Room zone temperatures are individually controlled by simple dial-type thermostats.
Please remember that underfloor heating takes longer to warm up and cool down
than conventional radiators and the timeclock settings should reflect this.
Ensure that each timeclock is set to your requirements as follows:-
Programming – day and time
1.
Open the cover. Press prog to enter
programming mode.
2. Press day to select day of the week.
Repeat until correct day is displayed.
3. Use + or - to adjust the time until
correct.
Programming – on/off times
4.
Press prog to enter on/off
programming mode.
5. Use + or - to adjust the 1st on time,
(setting number 1).
6. Press next to step to 1st off time,
(setting number 2).
7. Use + or - to adjust the 1st off time,
(setting number 2).
8. Press next and repeat steps 5 – 7
until all
on/off times are
programmed to suit.
9. If unit is pre-set for 24 hour operation
go to step 13, If a different cycle is
required, alter the internal pins and
continue with step 10 (see opposite).
10. Press day to advance to the next day
if different programming from the
previous day is required.
If the programme is the same, go
to step 11.
11. Press the copy button to copy the
previous day’s programming to the
current day.
12. Repeat steps 10 – 11 until all days
are programmed.
13. Press prog to return to run mode.