VLT
®
FCD Series
Basic standard
Burst
61000-4-4
Surge
61000-4-5
ESD
61000-4-2
Radiated
61000-4-3
Mains
distortion
VDE 0160
RF cm
voltage
2
61000-4-6
Acceptance
criterion
B B B A A
Port connection CM DM / CM Field DM CM
Line OK / OK OK
Motor OK
Control lines OK -/OK
1
OK
Relay OK -/OK OK
Profibus OK -/OK
1
OK
Signal interface
<3 m
OK
Enclosure OK OK
Standard bus OK -/OK
1
OK
Basic speci-
fications
Line 2 kV / DCN 2 kV / 4kV 10 Vrms
Motor 10 Vrms
Control lines 2 kV / CCC 2 kV/2
1
10 Vrms
Relay 2 kV / CCC 2 kV/2
1
10 Vrms
Profibus 2 kV / CCC 2 kV/2
1
10 Vrms
Signal interface
<3 m
2 kV / CCC
Enclosure 8kVAD
6kVCD
10 V/m
Standard bus
2 kV / CCC 2 kV/2
1
10 Vrms
DM: Differential mode
CM: Common mode
CCC: Capacitive clamp coupling (5 kHz)
DCN: Direct coupling network (5 kHz)
1. Injection on cable shield.
2. Electromagnetic clamp.
MG.04.A1.02 - VLT is a registered Danfoss trade mark
123
All about FCD 300