VLT
®
FCM Series
Programming
Warning word 1 [Hex] indicates one or more warnings
in a Hex code. See page 74 for further information.
Extended status word [Hex] indicates one or
more status states in a Hex code. See page
74 for further information.
Analog input 1 [mA] states the signal value on terminal 1.
Analog input 2[V] states the signal value on terminal 2.
010 Display line 1.1
(DISPLAY LINE 1.1)
Value:
Reference [%]
[1]
See parameter 009.
Function:
This parameter enables a choice of the first of three data
values to be shown on the display, line 1, position 1.
Description of choice:
There is a choice of 24 different data values,
see parameter 009.
011 Display line 1.2
(DISPLAY LINE 1.2)
Value:
Motor current [A]
[1]
See parameter 009
Function:
This parameter enables a choice of the second
of the three data values to be shown on the
display, line 1, position 2.
For Display read-outs, press the [DISPLAY/STATUS]
button, see also page 31.
Description of choice:
There is a choice of 24 different data values,
see parameter 009.
012 Display line 1.3
(DISPLAY LINE 1.3)
Value:
Power [kW]
[8]
See parameter 009
Function:
This parameter enables a choice of the third of the three
data values to be shown on the display, line 1, position 3.
Display read-outs are made by pressing the
[DISPLAY/STATUS] button, see also page 31.
Description of choice:
There is a choice of 24 different data values,
see parameter 009.
013 Local Control/Configuration as
parameter 100
(LOCAL CTRL/CONFIG.)
Value:
Local not active (DISABLE)
[0]
LCP control and open loop.
(LCP CTRL/OPEN LOOP)
[1]
LCP digital control and open loop.
(LCP+DIG CTRL/OP.LOOP)
[2]
LCP control/as parameter 100.
(LCP CTRL/AS P100)
[3]
LCP digital control/as parameter 100.
(LCP+DIG CTRL/AS P100)
[4]
Function:
This is where the desired function is to be selected
if Local control has been chosen in parameter 002.
See also the description of parameter 100.
Description of choice:
If Local not active [0] is selected, a possible setting
of Local reference via parameter 003 is blocked.
It is only possible to change to Local not active [0]
from one of the other setting options in parameter
013, when the FC motor has been set to Remote
control [0] in parameter 002.
LCP control and open loop [1] is used when the
speed is to be adjustable (in Hz) via parameter
003, when the FC motor has been set to Local
control [1] in parameter 002.
If parameter 100 has not been set to Spee d regulat ion
open loop [0], switch to Speed regulation open loop [0].
LCP digital control and open loop [2] functions as LCP
control and open loop [1], the only difference being that
= factory setting. () = display text [] = value for use in communication via serial communication port
MG.03.H3.02 - VLT is a registered Danfoss trademark
37

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT FCM Series and is the answer not in the manual?

Danfoss VLT FCM Series Specifications

General IconGeneral
BrandDanfoss
ModelVLT FCM Series
CategoryDC Drives
LanguageEnglish

Related product manuals