088037 Version 1.1 07.11.2019
Operation information, with accessories, continued
In AUTO mode the unit is controlled by the VOC, CO
2,
and RH% at
the same time.
VOC/CO
2
control:
If a VOC (accessory) or CO
2
-sensor (accessory connected via HAC)
is connected and the unit is set to AUTO mode the airflow is con-
trolled by the pollution concentration measured by the sensor.
VOC/CO
2
concentration is as follows:
Symbol
ppm
Description
< 600
Clean air
600 800
Adequate air quality
800-1200
Slightly polluted air
> 1200
Polluted air
Relative humidity in the room:
The filling up of the drop symbol indicates whether the relative humidity in
the house is within a comfortable area for the people and the home.
Symbol
Rel. hum. %
Description
< 24
Very dry air, fan step 1
25 - 34
Dry air, fan step 1
35 65
Comfort air, fan step 1-3
> 65
Humid air, fan step 3
Unit must be in AUTO mode in order to regulate in accordance with RH%.