16
Installer menu / installer mode
The installer menu is dedicated to skilled/experienced installers and service technicians
who have a thorough knowledge of ventilation plants.
The purpose of the INSTALLER MENU/MODE is to put the unit in a stat
e where the in-
staller can adjust the nominal air volume (fan step 3), without other functions or tem-
peratures of the unit preventing it. I.e. as long as the unit is in INSTALLER MODE fan
step 3 is maintained.
Warning:
Dantherm Air Handling A/S
disclaims any responsibility if the unit is installed in a way
that has a negative influence either on the heat consumption in the house, or the indoor
climate or if the unit is installed in such a way that the building, the building structure
and the furniture are damaged.
Start Installer
menu/mode
Press RIGHT for 10 sec. to activate the installer menu, until the ventilation unit icon on
the display is flashing slowly.
The installer menu will be active for 60 minutes or until the same button is pressed
Following menus and operating information are available in the installer menu:
Readout
H____
Readout AUTO pro-
gram No.
Readout supply fan
RPM
Readout preheater*
enable/disabled
Readout bypass cool-
ing* setpoint
Set auto program no.
(A1.....)
Set preheater* ena-
ble/disabled
Set bypass cooling* set-
point Tmin (T1 outside)
Readout SW for
HAC* A____
Set RH% *
(35-65% RH)
Set bypass cooling*
disable / set- point
Tmax (T3 inside)
*only operational if accessory module is installed
il
The following SW information can be viewed in the INFO LINE in the installer menu.
H101* = SW in Main control which is placed in the ventilation unit
F101*= SW in the remote control
A101*= SW in the accessory control
In AUTO menu you can select the desired AUTO programs. (A1..)
Continued overleaf