Oil Pressure Sender Characteristics
PGM
Parameter Definition
Unit
Factory Set
Description
P_136
Oil Pressure Sender Ohms -1
ohm
10
Oil Pressure Sender point 1, ohm value
P_137
Oil Pressure Value -1
bar
0.0
Oil Pressure Sender point 1, bar value
P_138
Oil Pressure Sender Ohms -2
ohm
52
Oil Pressure Sender point 2, ohm value
P_139
Oil Pressure Value -2
bar
2.0
Oil Pressure Sender point 2, bar value
P_140
Oil Pressure Sender Ohms -3
ohm
90
Oil Pressure Sender point 3, ohm value
P_141
Oil Pressure Value -3
bar
4.0
Oil Pressure Sender point 3, bar value
P_142
Oil Pressure Sender Ohms -4
ohm
140
Oil Pressure Sender point 4, ohm value
P_143
Oil Pressure Value -4
bar
7.0
Oil Pressure Sender point 4, bar value
P_144
Oil Pressure Sender Ohms -5
ohm
156
Oil Pressure Sender point 5, ohm value
P_145
Oil Pressure Value -5
bar
8.0
Oil Pressure Sender point 5, bar value
P_146
Oil Pressure Sender Ohms -6
ohm
184
Oil Pressure Sender point 6, ohm value
P_147
Oil Pressure Value -6
bar
10.0
Oil Pressure Sender point 6, bar value
Coolant Temperatıre Sender Characteristics
PGM
Parameter Definition
Unit
Factory Set
Description
P_148
Temperature Sender Ohms -1
ohm
38
Temperature Sender point 1, ohm value
P_149
Temperature Value -1
°C
100
Temperature Sender point 1, °C value
P_150
Temperature Sender Ohms -2
ohm
51
Temperature Sender point 2, ohm value
P_151
Temperature Value -2
°C
90
Temperature Sender point 2, °C value
P_152
Temperature Sender Ohms -3
ohm
134
Temperature Sender point 3, ohm value
P_153
Temperature Value -3
°C
60
Temperature Sender point 3, °C value
P_154
Temperature Sender Ohms -4
ohm
322
Temperature Sender point 4, ohm value
P_155
Temperature Value -4
°C
39
Temperature Sender point 4, °C value
P_156
Temperature Sender Ohms -5
ohm
650
Temperature Sender point 5, ohm value
P_157
Temperature Value -5
°C
20
Temperature Sender point 5, °C value
P_158
Temperature Sender Ohms -6
ohm
1630
Temperature Sender point 6, ohm value
P_159
Temperature Value -6
°C
02
Temperature Sender point 6, °C value
Fuel Level Sender Characteristics
PGM
Parameter Definition
Unit
Factory Set
Description
P_160
Fuel Level Sender Ohms -1
ohm
4
Fuel Level Sender point 1, ohm value
P_161
Fuel Level Value -1
%
0
Fuel Level Sender point 1, % value
P_162
Fuel Level Sender Ohms -2
ohm
31
Fuel Level Sender point 2, ohm value
P_163
Fuel Level Value -2
%
25
Fuel Level Sender point 2, % value
P_164
Fuel Level Sender Ohms -3
ohm
67
Fuel Level Sender point 3, ohm value
P_165
Fuel Level Value -3
%
50
Fuel Level Sender point 3, % value
P_166
Fuel Level Sender Ohms -4
ohm
110
Fuel Level Sender point 4, ohm value
P_167
Fuel Level Value -4
%
75
Fuel Level Sender point 4, % value
P_168
Fuel Level Sender Ohms -5
ohm
180
Fuel Level Sender point 5, ohm value
P_169
Fuel Level Value -5
%
100
Fuel Level Sender point 5, % value
P_170
Fuel Level Sender Ohms -6
ohm
1000
Fuel Level Sender point 6, ohm value
P_171
Fuel Level Value -6
%
100
Fuel Level Sender point 6, % value