I-Class
7
Specifications
7.1 General
Bar Codes
Code 39, Interleaved 2 of 5, Code 128 (subsets A, B and
C), Codabar, LOGMARS, UPC-A,
UPC-E, UPC 2 & 5 digit addendums, EAN-8, EAN-13, EAN 2 & 5 digit addendums, UPC
Random Weight, Code 93, Plessey, Universal Shipping Container Symbology, Code 128 MOD
43, Postnet, USS/EAN-128 Random Weight, Telepen, USD-8 (Code 11), UPS MaxiCode
(modes 2 & 3), PDF417, Data Matrix, QR Code, Aztec, and MicroPDF417. (See the Class
Series 2 Programmer’s Manual for details.)
Fonts
9 Bit-Mapped Fonts; CG Triumvirate Scalable Font; and, CG Triumvirate Condensed Bold
Scalable Font. (See the Class Series 2 Programmer’s Manual for details.)
Communications
Interfaces: EIA RS-232/DB-25 Serial & IEEE 1284 Compliant Parallel
Serial Data Rates: 1200, 2400, 4800, 9600, 19.2K, and 38.4K baud.
Handshaking: Xon / Xoff & CTS / DTR
Parity: Even, Odd, or None
Stop Bits: 1 or 2
Data Bits: 7 or 8
Electrical
Input Voltage: 90 – 132 or 180 – 264 VAC @ 47–63 Hz, auto-ranging.
Power Consumption: Typical Operating: 90 Watts; Standby: 10 Watts
Grounding: Unit must connect to a properly grounded receptacle.