Fiscal Printer DATECS FP-2000 Version 3.10
Text A text of no more than 40 symbols sent for displaying. If symbols with ASCII codes smaller than
20h (control symbols) they are increased with 40h and are preceded by 10h.
Example: To send 1Bh, 4Bh, 00h the data field will have to contain 10h, 5Bh, 10h, 40h.
65H (101) SETTING THE OPERATOR’S PASSWORD
Data field: <OpCode>,<OldPwd>,<NewPwd>
Response: None
OpCode Operator’s code (1 to 16)
OldPwd Old password (4 to 8 digits)
NewPwd New password (4 to 8 digits)
Sets one of the 16 operator’s passwords, which will be demanded upon opening a fiscal receipt. After three
erroneous password entries, the printer will block, it must then be switched OFF and ON again to continue operating.
After initialization or reset of the operational memory, all 16 passwords are “0000”.
66H (102) ENTERING OPERATOR’S NAME
Data field: <OpCode>,<Pwd>,<OpName>
Response: None
OpCode Operator’s code (1 to 16)
Pwd Password (4 to 8 digits)
OpName Name of the operator (up to 24 symbols)
Enters one of the 16 operator names. The number and the name of the operator are printed at the beginning of each
fiscal (clients) receipt. After three erroneous password entries the printer will block, it must then be switched OFF and
ON again to continue operating. After initialization or reset of the operational memory all 16 passwords locations are
empty.
67H (103) INFORMATION ON THE CURRENT RECEIPT
Data field: None
Response: CanVd,TaxA,TaxB,TaxC,TaxD,TaxE,TaxF,TaxG,TaxH,TaxI
CanVd Possible/impossible return (sale registration with a negative sign) [‘0’ / ’1’]
TaxX The sum accumulated for each VAT group (9 digits with sign each field)
The command offers information on sums accumulated so far under the different tax groups and whether it is
possible to return the registered items sold.
68H (105) OPERATOR’S REPORT
Data field: None
Response: None
Information on the sales, performed by the operators, is printed out where for each separate operator the following
data is printed out: name, individual number, number of fiscal receipts, discharges made, surcharge, sum adjustments
and accumulated total sums.
6AH (106) DRAWER KICK OUT
Data field: [<mSec>]
Response: None
mSec The length of the impulse in milliseconds (5-100)
Sends an impulse for opening the cash drawer. This parameter sets a new value for the length of the impulse, which
is stored in the memory of the printer. If this parameter is skipped, the last entered value remains valid. After memory
RESET a value of 15 ms is set.
6BH (107) DEFINING AND READING ITEMS