EasyManua.ls Logo

Datecs FP-2000 - Page 29

Datecs FP-2000
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fiscal Printer DATECS FP-2000 Version 3.10
Num Journal number
Cnt Last Z-report
Line Last written line number.
TotLines Total written journal lines.
FreeLines Free lines count in el. journal.
TotLines Total lines count in el. Journal
If Cmd isF’,PL’ or PSData field syntax is:
[<EJReportType>[,<Period>]]
EJReportType
F Full journal report (info and lines) for every receipt in current period.
L Only lines for every receipt in current period.
I Only info for every receipt in current period.
Period syntax is:
[<D>]ZReceipt1[,[ZReceipt2]][,ZReceipt3,RReceipt2]
If Period is empty, the period is entire Electronic Journal.
D if there is D ZReceipt1 or/and ZReceipt2 are DATE TIME in format
YY[MM[DD[hh[mm]]]]. Only YY of ZReceipt1 is needed, the other fields are
01010000,YY12312359 i.e. it can be done Year, Month, Day, Hour or Minute journal
report without typing second field.
ZReceipt1 If only this parameter is present, the period will be only for that ZReceipt
(without any other receipts). If there is comma after ZReceipt1 the period will
be from that ZReceipt till end of the Electronic Journal (with all receipts (R and
X) in it).
ZReceipt2 The period will be from ZReceipt1 to ZReceipt2 ZReceipts (with all receipts (R
and X) in it).
ZReceipt3 and RReceipt2 The period will be from ZReceipt1 ZReceipt and ZReceipt2
RReceipt to ZReceipt3 ZReceipt and RReceipt2 RReceipt
(with all receipts (R and X) in it).
F Get first journal line in period. RespData Syntax:
‘F’ or ‘P,<Text>’
F No journal line found
P Journal line successfully read
Text The journal line, ready to be stored in a file.
N Get next journal line. Data field is empty. RespData is the same as ‘Fsubcommand.
PL Print journal using normal font size. If Data field is empty device print electronic journal starting
from the last ZReport, than all journal lines in current Z day. If Data present it will work like ‘F’
subcommand, but period will be printed, not downloaded.
PS Print journal using half-height font size. If Data field is empty device print electronic journal
starting from the last ZReport, than all journal lines in current Z day. If Data present it will work
like ‘Fsubcommand, but period will be printed, not downloaded.
CL Continue ‘PL’ or ‘PS’ without Data (start with the first non-printed receipt) using normal font
size. Data must be empty.
CS Continue ‘PL’ or ‘PS’ without Data (start with the first non-printed receipt) using half-height
font size. Data must be empty.
7AH (122) ENABLE / DISABLE TRAINING MODE
Data field: [<NewMode>]
Response: OldMode
NewMode One byte with possible value ‘0’ or1’:
‘0’ Disable training mode.
‘1’ Enable training mode.
OldMode The value before executing the command. One byte with possible value ‘0’ or ‘1’:
‘0’ Disable training mode.
‘1’ Enable training mode.

Related product manuals