Fiscal Printer DATECS FP-2000 Version 3.10
A clear display command is sent. If a fiscal receipt is opened and SW4 is OFF only the lower line is cleared.
23H (35) TEXT ON THE LOWER LINE OF THE DISPLAY
Data field: <Text>
Response: None
Text A text of up to 20 symbols sent directly to the display. Prior to this a command for positioning
and clearing the lower line is sent automatically from the printer.
24H (36) SET LAN SETTINGS
Data field: [<IPAddr>,<SubnetMask>,<TCPPort>,<DefGateway>[,<MACAddr>]]
Response: [<IPAddr>,<SubnetMask>,<TCPPort>,<DefGateway>,<MACAddr>]
IPAddr 4 numbers up to 255 separated with dot, represented device IP address.
SubnetMask 4 numbers up to 255 separated with dot, represented device Subnet mask.
TCPPort 4 numbers up to 255 separated with dot, represented device IP port.
DefGateway 4 numbers up to 255 separated with dot, represented device Default Gateway.
MACAddr Up to 8 hexadecimals symbols represented device MAC address. Works only with service
jumper!!!
If there no data field returns current settings.
26H (38) OPENING A NON-FISCAL RECEIPT.
Data field: None
Response: NFReceipt
NFreceipt The number of non-fiscal receipts since last daily closure on (4 bytes).
The FP performs the following actions:
Prints the header and the tax registration number of the seller
Prints operator number and name
A response is send which contains NFreceipt
The command is not permitted if:
The fiscal memory has not been formatted
There is an opened fiscal receipt
There is an opened non-fiscal receipt
The clock is not set
27H (39) CLOSING A NON-FISCAL RECEIPT.
Data field: None
Response: NFReceipt
NFreceipt The number of non-fiscal receipts since last daily closure on (4 bytes).
The FP performs the following actions:
- Prints the footer
- The date and hour of the document are printed
If the S1.1 flag is raised the command is not executed because there is no opened non-fiscal receipt.
29H (41) SET MEMORY SWITCHES
Data field: [<Switches>]
Response: None
Switches 8 bytes with value ‘0’ or ‘1 the configuration switches.
The command writes to flash memory the switches value, graphics logo, barcode height, print darkness and default
drawer pulse length. After RAM reset they are restored with the saved values.
If the switches parameter is not present, then the old switches are kept.