User’s Manual1 DATECS LP-1000
28 29
Format: ZT or ZB
ZT Normal image
ZB Image rotated to 180
o
Set date and hour
The command is used to set the real-time clock of the printer.
Format: TSm,d,y,h,m,s
m month (1 - 12)
d day (1 - 31, validity of the date being checked)
y year - the last two digits (0 - 99).
h hour (0 - 23)
m minutes (0 - 59)
s seconds (0 - 59)
Example: TS10,2,01,14,10,10
Sets clock to 2 Oktomber 2001, 14:10:10
Setting date format
The command sets the mode in which the string will generate the
current date.
Format: TDAxByC
With capital letter the fields for the date have been
marked. A, B and C may have the following values,
which may be used not more than once:
Y2 or Y4 The current year, marked with 2 or 4 digits.
ME or MN The current month shown in three letters
or two digits.
DD The current day of the month.
The small letters mark the spaces between the fields. They are
entered together with the symbol, which we wish to use. The divisors
between the fields are marked in small letters - entered immediately
after the symbols we wish to use.
Example: TDdd-me-y4
This would generate a date of the type: 02-OKT-2001
Setting the length of the page
Format: Qm,[B]n[+p]
m is the length of the printed area. Possible values are
between 80 (10) and 4000 (500 mm).
B is an optional parameter (the letter ‘B’), which selects
labels with black line on the back.
n is the added space after the printout. Possible value -
not more than 255 (32 mm). Not used when printing on
labels.
p is an optional parameter, determining the additional
offset of the printable area when using labels with black
line.
When paper rolls are used sets the vertical size of the printing area
and the automatic space added after it. Both sizes are in dots: 8 dots/
mm or 203 dots/inch. If there are elements outside of this size when
the image is generated they will be cut off.
Example: Q240,80
Sets the length of the page - 30 mm - and dividing space
10 mm. When sticker-labels are used sets the borders of
the label, and prints exactly one image per label. In spite
of this the parameters must be within the set limits as
quoted above.
Setting the starting point of the print
Sets the starting point of the printing area.
Format: Rm,n
m is the horizontal offset. Possible value is 0 - 607.
n is the vertical offset. Possible value is between 0
and 3999.
Example: R24,24
Sets an initial offset on X and Y of 3 mm.
Setting the print direction
Sets the position of the image during print.