NOTE: The Torrium2 controller tted to this pump is adaptive. If your pump draws
air or is subject to blockage, the Torrium2 adapts to its new maximum pressure. This
may result in your system pressure not dropping below the new cut-in pressure and
your pump not starting. Should this occur, re-prime your pump units as detailed
above. Should this not prove successful, it is likely you have a blockage in the pump.
You should contact your Davey dealer for assistance.
NOTE:
a) For protection, the Davey
®
pump motor is tted with an automatic “over
temperature” cut-out. Constant tripping of this overload device indicates a
problem e.g. low voltage at pump, excessive ambient temperature (above 115°F)
in pump enclosure.
b) The Torrium2 control device may have to be reset after rectifying any of the
above operating troubles. This is done by pushing in the “prime” button and
releasing it after 2 seconds, or switching the power supply off then on.
Motor normally operates at high temperature and may be too hot to touch.
Before handling pump or motor, stop motor and allow it to cool.
During servicing, use only approved, non-petrochemical based oring and
gasket lubrication. If unsure, consult your Davey Dealer for advice.
WARNING: Do not use hydrocarbon based or hydrocarbon propelled
sprays around the electrical components of this pump.
This pump is not to be used by children or inrm persons and must not be
used as a toy by children.
WARNING: When servicing or attending pump, always ensure power is switched
off and lead unplugged. Electrical connections should be serviced only by qualied
persons. If the electrical supply lead of this pressure system is damaged, it must be
replaced.
Care should also be taken when servicing or disassembling pump to avoid possible
injury from pressurised water. Unplug pump, relieve pressure by opening a tap on
the discharge side of the pump and allow any hot water in the pump to cool before
attempting to dismantle.
NOTE: To protect the pump, the Torrium tted to your pump has a secondary over
temperature function built-in. This function automatically stops the pump should the
water in the pump reach 160
o
F. The pump will automatically restart once the water
temperature drops below 140
o
F.
After Sales Service
For professional after sales service or repair please
call USA: 866.328.7867 or visit www.daveyusa.com
12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Davey BT14-300 and is the answer not in the manual?

Davey BT14-300 Specifications

General IconGeneral
BrandDavey
ModelBT14-300
CategoryWater Pump
LanguageEnglish

Related product manuals