Prior to using this pump you must ensure that:
The pump is installed in a safe and dry environment
The pump enclosure has adequate drainage in the event of leakage
Any transport plugs are removed
The pipe-work is correctly sealed and supported
The pump is primed correctly
The power supply is correctly connected
All steps have been taken for safe operation
Appropriate details for all of these items are contained in the following Installation
and Operating Instructions. Read these in their entirety before switching on this
pump. If you are uncertain as to any of these Installation and Operating Instructions
please contact your Davey dealer or the appropriate Davey ofce as listed on the
back of this document.
Congratulations on your purchase of a high quality, Davey pressure system. All
components have been designed and manufactured to give trouble free, reliable
operation.
Your new pressure system incorporates ‘Torrium2’, electronic ow controller – a
Davey designed unit that enables the use of a highly efcient pump design and
offers the following benets:–
1. Enables the pump to deliver a constant ow of water particularly at low ow
rates – reducing the inconvenience of pressure variation in showers etc.
2. Provides automatic “cut-out” protection should the pump run out of water or
overheat*, should the pump fail to start due to low voltage or a blockage in the pump.
3.
Provides an easy to understand visual representation of the system status.
4. Has adaptive pressure cut-in which allows the pump to start at approximately
80% of the maximum pressure at last shut-down. This allows the controller to
accommodate varying inlet pressures and pump performance.
5. Automatic retry functions in the event of a critical system fault.
6. Easy visual guide to the status of the inbuilt surge arrestor.
7. Choice of both vertical and horizontal outlets.
* Motor overload / overheat protection included. Motor has its own overload /
overheat protection.
Before installing your new pump, please read all instructions carefully as failures
caused by incorrect installation or operation are not covered by the guarantee. Your
Davey pressure system is designed to handle clean water. The system should not be
used for any other purpose without specic referral to Davey. The use of the system to
pump ammable, corrosive and other materials of a hazardous nature is specically
excluded.
NOTE: Prior to installation remove the red transport plugs from the suction and/or discharge.
1. Torrium2 Priming Plug
2. Torrium2 Control Module
3. Discharge Outlet
4. Suction Inlet
5. Pump Body
6. Motor
7. Priming Plug (pump)
8. Stainless Steel Hose
(1”F x 1”F)
4
5
6
7
8
2
1
3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Davey BT14-300 and is the answer not in the manual?

Davey BT14-300 Specifications

General IconGeneral
BrandDavey
ModelBT14-300
CategoryWater Pump
LanguageEnglish

Related product manuals