Removal of the Pump from Pipework
Should it be necessary to remove the pump, follow these instructions:
1. Switch off the power and remove the plug from the power source.
NOTE: If the pump is wired into a time clock or another automatic control,
thewiringshouldberemovedbyaqualiedtechnician.
2. Close the water valves on the pool return and the pump inlet pipework.
3. Remove the discharge & suction barrel unions taking care not to lose
the o’rings.
4. Move the pipework with the barrel unions attached until the pump can
be pulled clear.
NOTE: When making any enquiries about your PowerMaster
®
be certain
to quote the model number from the nameplate located on the motor.
Water Quality
Maintaining balanced water chemistry is important to the life of your pool
pump. This pump is designed to be used with Pool & Spa water, balanced
inaccordancewithLanglierSaturationIndex,withapHlevelofbetween
7.2 and 7.8 and is regularly treated with a chlorine sanitising agent with the
level not exceeding 3.0 ppm.
Please consult your local pool shop regularly to have your water tested.