Low Energy Operation:
Your ProMaster
TM
VSD Eco-Series pump has speed settings from
1500 to 3600 RPM:
- 1500 – Lowest Speed, 1
- 3600 – Highest Speed, 10
- 3800 – Backwash Speed
• Speed 1 provides the lowest speed and therefore the greatest energy
efficiency and savings. See page 9 for all other dial position speeds.
Operation Recommended Speed Setting
Pool Filtration Speed 1 to 4
Suction pool cleaner operation Speed 5 to 8
Backwashing your media filter Backwash Speed
Manually cleaning your pool
Speed 9 to 10
Water Feature operation
Spa Jet operation
Solar pool heating
Guidelines for Recommended Pump Operating Hours:
Australian Standards AS3633: “Private swimming pools - water quality”
states that “The minimum turnover rate shall be a single turnover of the full
volume of the pool water, within the period that the pump would normally be
operating….”
The table below provides a guide only to the running times of your pump
while in filtration mode in order to achieve the minimum turn over rate:
Pool Size
(Litres)
Speed Setting (hours)
Speed 1 Speed 5 Speed 10
20,000 3.3 1.7 1.1
30,000 5.0 2.5 1.7
40,000 6.7 3.3 2.2
50,000 8.3 4.2 2.8
60,000 10.0 5.0 3.3
80,000 13.3 6.7 4.4
100,000 16.7 8.3 5.6
8
NOTE: Whenever you increase the pump run time, you should decrease
the chlorine output of your chlorinator to avoid the risk of over chlorination.