3
Selection
The Torrium2 controller is available in different versions to suit different single phase pump
models up to 10amp maximum run current. Please ensure you have the right unit for the
pump model (see table below).
Torrium2
Model
To Suit
Standard
Voltage/Hz
Pump System
TT45
110-240
/ 50-60
A pump or total system* capable of no more than 450kPa maximum
shut-off head or dead head pressure.
TT70
110-240
/ 50-60
A pump or total system* capable of at least 450kPa, but no more than
750kPa maximum shut-off head or dead head pressure.
*‘total system’ includes maximum incoming pressure and pump pressure (e.g. mains boosting)
NOTE: While Torrium2 can be connected to pumps of nearly all single phase voltages
commonly used worldwide, special models with power leads to suit particular regions or
countries are made. For example, for North America, 110-120V, 60Hz models use sufx ‘Y/
USA and 220-240V 60Hz models use sufx “P/USA”
NOTE: The above table assumes the pump is installed with a small ooded
suction, or a normal suction lift. High incoming pressures may require a
different installation procedure - consult your Davey dealer for assistance.
Fitment of the Torrium2 controller
The Torrium2 controller ts onto the outlet of the pump.
The Torrium2 controller is designed to t in place of a Davey Torrium or Hydrascan, a
Presscontrol or can be installed to replace another form of controller eg. pressure switch.
Figure 1
Rotary Coupling Inlet
1” Male
Horizontal Outlet
1” Male
Priming Cap which covers the 1” Male Vertical Outlet
and access to the internal check valve.
Status Indicator
Lights
Prime Button