CONTROLLER DIAGNOSTIC CHART
Condition Troubleshooting
Controller does not operate / No display
Blown fuse
Check all the wire connections
12V voltage indicator flashing
Controller receiving low voltage <
10.5V
Controller receiving high voltage >
17.5V
24V voltage indicator flashing
Controller receiving low voltage <
21.5V
Controller receiving high voltage >
27.5V
Sensor open circuit
Check sensor wiring for any open
circuits
Sensor short circuit
Check sensor wiring for any short
circuits
Low Temp
<40°C (104°F) after 5 Minutes
Check engine temperature
Above Set Temperature
Sensor temperature is at least 10°C
(18°F) above the set temperature.
Pump Error
Check pump wiring for open/short
circuits
Override ON
EWP manually override by the user.
To turn OFF, Press & hold the set
button for 5 to 7 seconds or switch
OFF & ON the IGN.
ERR Temp sensor Open or Short circuit