CONTROLLER FUNCTIONALITY
The controller offers the following control functions:
• Settable minimum and maximum frequency and open circuit voltage.
• Display of operating parameters including frequency, voltage, amperage, input
power and pump speed.
• Protection against over and under voltage, over current, system overload and
module over temperature.
• Fault detection with error code display.
• Selectable hybrid modes that prioritise solar supply as well as maximise output
through optimal blending of both power supplies.
Ÿ Power saving mode (CRUISE) - limit the maximum AC input power, hence saving
energy.
INSTALLATION
Dayliff Sunverter 4 controllers are surface mounted and should be provided with a housing
for water and heat protection. Due to the high operating voltages proper earthing is
essential, which must be done by a qualified electrician. As a rule, all PV powered solar
pumping systems should be provided with a solar module array with a nominal output
about 30% greater than the motor size. In hybrid applications, higher array MPP voltage is
specified to allow achievement of larger solar supply share of hybrid power supply. The
arrays should be wired in a combination of series and parallel connections to ensure that
the correct voltage is available into the inverter. It is important that the connection
arrangement is approved by the pump supplier.
OPERATING CONDITIONS
Altitude: 0-2,000m**
0 0
Ambient Temperature: -20 C to 60 C ***
Relative Humidity: 0-95% (non condensing)
Frequency: 0-60Hz
CONTROLLER DATA
**If the altitude is over 2,000m, the rated output current should be derated by 10% for every 1,500m increase in height
Model
Motor
Rated
Power
(kW)
Output
Current
(A)
2.2
Weight
(kg)
Dimensions (mm)
WH D
Rated
Voltage
14
266
111
5.5
Max
DC
Input
Voltage
VDC
440
1.1
8.6 125-360
180-360
1.5
1x240V
11
250-360
296
MPP
Voltage
VDC,
Solar
MPP
Voltage
VDC,
Hybrid
125-370
180-370
SV4/3.0M
SV4/1.5M
SV4/2.2M
250-370
All dimensions in mm