EN-8
PAR. PROCEDURE
PROGRAMMING
PROCEDURES
Positioning of gate/door
Unused parameter
Memorization of the motor stroke
Deletion of the radio receiver memory
Memorization of transmitters
Search and deletion of a transmitter
Resetting of default parameters
PAR. PARAMETER DESCRIPTION
OPERATING PARAMETERS
Type of coding of the radio receiver
Channel selection and linking to “start” and “pedestrian” inputs
Motor speed during normal stroke (calculated as % of max speed)
Motor speed during slow-down phase (calculated as % of max speed)
Slow-down duration (expressed as % of total stroke)
Unused parameter
Motor force in opening (if =100 --> max force, obstacle impact sensibility deactivated)
Motor force in closing (if =100 --> max force, obstacle impact sensibility deactivated)
Unused parameter
Unused parameter
Selection of type of external safety device: rib / barrier. If the “rib” mode is selected, when the CST input
is activated the movement direction is inverted; If the “barrier” mode is selected, when the CST input is
activated the movement is stopped.
Time of automatic closing (expressed in sec). If=0 the automatic closing is deactivated
Time of pre-fl ashing (expressed in sec)
Recording delay of closing limit switch: if= 1, when the door arrives on FCC, the operator stops after about
1 min. delay. If door arrives at the stroke while this delay, the operator immediately stops. Figure set by the
factory: “0”.
Ramp rate duration
- If=0 the motor starts immediately at the selected speed
- If=1 the motor speeds up progressively until it reaches the selected speed