EN-5
5 USE INSTRUCTIONS
1 Power Supply
After making all connections to the terminal board, remember to short-circuit, whenever needed, any unused input (see “connection to the
control board”) and power the card: on the display you will read for a few seconds “rES-” followed by the symbol “- - - -” which stands for gate
closed.
2 Visualisation of inputs status
By pressing the “OK“ key when the control board awaits further
instructions (“- - - -”) the display shows some vertical segments:
each one of them is associated to one of the control board
inputs. When the segment is lighted it means that the contact
associated to it is closed, on the contrary, when it is not lighted
the contact is open.
CST
PED
FCC
FCA
STOP
FOTO
START
WARNING During the programming of motor stroke, the control board detects automatically the presence and type of photocells, safety
devices and limit switches installed. It is therefore essential that during this phase all above devices are properly connected and in
operation.
WARNING BEFORE STARTING THE PROGRAMMING OF MOTOR STROKE, IT IS RECOMMENDED TO SELECT THE TYPE OF OPERATOR YOU
INTEND TO USE: PARAMETER P034=0 OPERATOR WITH ENCODER; P034=1 OPERATOR WITHOUT ENCODER.
3 Motor stroke learning
3.1 Door/gate positioning
Instructions Function Display
1. Scroll down the parameters until you visualize procedure P001
2. Confi rm! The control board is ready for the positioning of the gate/door
3. Position gate/door in its standstill position after opening
1
4. Confi rm! The control board has memorized the gate/door position
3.2 Motor stroke learning
Instructions Function Display
1. Scroll down the parameters until you visualize procedure P003
2. Confi rm! The control board awaits a further confi rmation
3. Confi rm by pressing on the OK key for a few seconds! The procedure starts
4.
Now the gate/door starts to close at a slow speed until it reaches the stroke end while closing (or the
limit switch).
5. On the display you will read “- - - -”. Motor stroke memorization done!
WARNING If during the door opening you have no access to the push buttons of the control board, you may confi gure and memorize the
stroke by using the buttons of a 4-channel remote control stored in memory.
3.3 Door/gate positioning and Motor stroke memorization
Instructions Function Display
1. Scroll down the parameters until you visualize procedure P001
2. Confi rm! The control board is ready for the positioning of the gate/door
3. Position gate/door in its standstill position after opening
1
4.
Confi rm! Now the gate/door starts to close at a slow speed until it reaches the stroke end while clo-
sing (or the limit switch).
5. On the display you will read “- - - -”. Motor stroke memorization done!
1
By pushing the button the gate must open, by pushing the button the gate must close. If this does not happen, you must turn the control board off,
swap the two motor cables (clamps 4 and 5) and give power supply to the control board again. Only in case you use limit switches, fi rst of all position the
gate where you want it to stop in closing and then adjust the closing cam so that it presses on the closing limit switch in that point. Then position the gate in
the opening position and adjust the opening cam so that it presses on the opening limit switch in that point.