EN-3
2 PRODUCT DESCRIPTION
The 400RR control board has been manufactured exclusively to control DEA System automatisms, with 400V 3 three-phase motor~
with or without magnetic encoder. The environment for which it has been designed and tested is the “normal” situation for industrial
openings; the degree of protection from dust and water is indicated in the speci c instruction manuals of each DEA System automatism,
onto which the 400RR control board is mounted. In the case of control units supplied in a BOX, the protection rating is IP 55, if installed
correctly.
3 TECHNICAL DATA
Power supply (V) 400V 3~ ±10% (50Hz)
Flashing light output 230 V ~ max 75mA art. LED230AI
Auxiliary power supply output (24VAUX)
+24 V ~ max 400mA (24Vaux + 24Vsic)
Safety devices power supply output (24VSIC)
Electric lock output 12 V ~ max 15VA (max 1 art. 115)
LC/SCA contact capacity max 5A
Max motor capacity 1200W
Fuse F5=F6=F7 T5A 250V retarded
Fuse F8 !!NOT INSTALLED!!
Fuse F9 T400mA retarded
Operating temperature range -20÷50 °C
Radio receiver frequency 433,92 MHz “rolling code / dipswitch”
Max. number of transmitter controlled 100