8  ADVANCED PROGRAMMING
Below • nd the description of some programming procedures relative to the management of the radio-commands memory and advan-
ced con• guration of the command inputs.
To access the control unit advanced programming functions, remove the Jumper J4 from the board. Use the   and   keys to go to 
P005 and hold the 
 key down for 5 seconds (at this point, all of the parameters are visible and can be modi• ed).
1  Visualisation of inputs and operations-counter status
1.  Scroll the parameters with  the   and   keys until  the screen reads 
P013;
2.  Access the parameter by pressing the   button;
3.  The “Input Status” is shown on the screen (check that this is correct):
 
4.  Press the   button again;
5.  The  “Total  Operation  Counter”  is  shown  on  the  screen
(* see P064):
Ex: 
 = 3x1000* = 3000  operations executed
6.  Press the 
 button again;
7.  The “Maintenance  Operation  Counter” is  shown  on  the  screen  (*  see 
P065):
Ex: 
 = 5*x500 = 2500  operations still to be carried out before 
the maintenance intervention request (
 = maintenance operation 
counter disabled)
8.  Press the 
 button again to exit the parameters (P013 is shown on the 
screen again).
2  Transmitters coding selection
1.  Scroll down the parameters with   and   keys until you visualise 
P027;
2.  Con• rm by pressing on the   key;
3.  Select the type of transmitter by scrolling 
 and   keys:
  - d000=• x rolling-code (suggested);
  - d001=complete rolling-code;
  - d002=dip-switch;
4.  Con• rm by pressing on the 
 key (display shows again P027).
Warning: If you need to vary the type of encoding, and only if other remo-
tes with different encoding  are memorized, you need to erase memory 
(P004) AFTER you have set the new encoding.
3  Adjustment of operating parameters
If you need  to modify the operating parameters (force, speedness 
etc..):
1.  Scroll down the parameters until you visualize the desire param-
eter (i.g. P032);
2.  Con• rm by pressing on the 
 key;
3.  By pressing on 
 and  , set up the desired value;
4.  Con• rm by pressing on the 
 key (display shows the parameters 
previously selected).
For the complete list of the “Operating Parameters” See the 
table on page. 33.