7.2  Uploading data from an external memory unit (UPLOAD)
1.  Scroll down the parameters with 
 and   keys until you visualize P012;
2.  Press the 
 key, the display visualizes the word “ ” ! ashing;
3.  Press the 
 again and continue pressing for 5 sec (if you release it before this period, the procedure is stopped);
4.  Release the 
 key as soon as the word “ ” stops ! ashing;
All the control panel con" gurations (TYPE, parameters, remotes, operators stroke, etc..) contained in the external memory unit are 
uploaded in the connected control panel;
5.  At the end of the operation display returns to P012.
WARNING If you are not connected to any MEMONET units or if the connecting cable is disconnected during the data transfer operation, 
the display will visualize 
, then the control unit is entirely reset and the display shows the word “TYPE” fl ashing. 
Refer to the MEMONET instruction to restore command unit functioning.
8  Inputs confi guration
Where the installation requires different commands and / or additional to 
the standard ones  described by plan, you can con" gure each input for the 
operation desired (eg. START, PHOTOS, STOP, etc ...).
1.  Scroll down the parameters with the 
 and   to see that corresponding 
to the desired one:
  #  P018=for INPUT 1;
  #  P019=for INPUT 2;
2.  Con" rm by pressing on the   key  to get access to the parameter (eg. 
P018);
3.  Scroll down with the 
 and  , keys to set the value corresponding to 
the desired operation (refer to table “Input Con" guration parameters” on 
page 32);
4.  Con" rm by pressing on the 
 key (display shows again P018).
5.  Execute the new connection to the input just recon" gured.
9  Programming complete
WARNING At the end of the programming procedure, re-introduce Jumper J4, until “- - - -” is shown on the display and close the lid of 
the electric box. The automatism is now in stand-by for normal operating commands.