DECATHLON SERIES GAS FRYERS
CHAPTER 1: SERVICE PROCEDURES
1-23
1.7.8 Replacing the Frypot (cont.)
6. Carefully pry the capping strip off with a screwdriver
or similar tool and set aside. Be careful not to bend
the capping strip during removal.
7. Locate all screws securing back panels. Screw location and orientation will vary according to
fryer model.
8. Remove back panels on fryer. Retain screws for re-
assembly.
9. Remove screw securing brace (and back panel) to flue
cap. Support brace with hand while removing screw
to prevent brace from falling away. Remove brace
and set aside for reassembly.
T
yp
ical screw locations on the back
Removing brace holding back panel to flue cap.
Removing capping strip.