EasyManua.ls Logo

Debem BOXER Series - 6.1 Scheduled Maintenance Table

Debem BOXER Series
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
of
INDUSTRIAL PUMPS
www.debem.com
rev
6.1 SCHEDULED MAINTENANCE TABLE
The scheduled maintenance operations are reserved for qualied and authorised Mechanical Service-
men, equipped with suitable Personal Protective Equipment (PPE), who know and comply with the con-
tents of this Manual.
To ensure optimal performance and safe use of the pump, it is necessary to periodically perform the
routine maintenance operations indicated in the following table and dealt with in the following sections.
The timing of the reported operations refers to use under normal conditions; for harsh installations and
operating conditions, the indicated ranges must be downgraded accordingly.
SEC. SCHEDULED MAINTENANCE
every
500
hours
500.000
cycles
10.000.000
cycles
20.000.000
cycles
6.2
EXTERNAL CLEANING AND TIGHTNESS
CHECK:
check check replacement
6.2.1 • External cleaning of the Pump
-- -- --
6.2.2 • Product Circuit Tightness Check
-- -- --
6.3 TIGHTNESS CHECK
check check replacement
6.3.1 • Tightness check
--
-- --
6.3.2 • Tightening torque table
--
-- -- --
6.4 PRODUCT CIRCUIT MAINTENANCE:
check replacement
6.4.1 • Pump Disassembly
-- --
6.4.2 • Internal cleaning of the product circuit
-- --
6.4.3 • Check and/or replacement of valves
-- --
6.4.4 • Check and/or replacement of diaphragms
-- --
6.4.5 • Pump Re-assembly
-- --
6.5 AIR CIRCUIT MAINTENANCE
6.5.1 • Pump Disassembly When necessary
6.5.2 • MICROBOXER Exchanger Replacement 50.000.000 cycles
6.5.3 • BOXER Coaxial Exchanger Replacement 50.000.000 cycles
6.5.4 • Pump Re-assembly When necessary
CAUTION
In the presence of heavy uses (concentrated corrosive liquids or liquids that crystallise), it is necessary to
increase the frequency of operations.
CAUTION: risk of internal back-pressures and projection of components during disassembly.
In severe conditions (incorrect installations and/or stops and/or in stall conditions), residual pressures inside
the pump can be generated which are not discharged. Before opening and disassembling the pump, it is
necessary to secure the pump casings with a suitable ratchet strap and wear suitable Personal Protective
Equipment (PPE).