8.2 DISPOSAL
This operation is reserved for trained and qualied Mechanical Servicemen, equipped with suitable Per-
sonal Protective Equipment (PPE); see the Technical and Safety Data Sheets of the treated liquid.
CAUTION: risk of contact with toxic or corrosive uids.
The identication plate of your BOXER pump indicates the construction materials of the components as
described in Section 2.2 PUMP CONFIGURATION CODE so that you can carry out the separation and
disposal by type of homogenous materials.
BOXER pumps do not contain dangerous parts or that require conditioning treatments, however, they
may be contaminated due to the environment of use or the type of uid used. However, when they are
worn out, they must be disposed of and demolished in the following manner:
CAUTION: risk of serious injuries, harm to health.
Do not dispose of the pump with residues of dangerous uids or with surfaces contaminated by toxic,
irritating and/or health damaging uids.
 Wash, remove or adequately decontaminate any product residues or contaminants that are dangerous to human
contact and/or to the environment, working according to the instructions given in the relevant Technical
Data Sheet or Safety Data Sheet of the Product used.
 Wash the inside of the pump product circuit (washing, decontamination according to the used uid) with a suitable
detergent or decontaminant.
 Close the product suction and delivery on/off valves of the pump.
 Close the air supply using the 3-way valve and discharge the residual pressure from the pneumatic circuit inside
the pump and then disconnect the air supply on the network node.
 Disconnect the compressed air supply pipe from the pump.
 PUMP DISASSEMBLY
Proceed as follows to disassemble the pump.
Safety requirements before starting the operation:
• Pump stopped with air supply disconnected and interlocked and residual pressure discharged;
• Pump with the external parts cleaned/washed;
• Pump with internal product circuit washed and/or decontaminated (according to the pumped liquid).
• Closed product sectioning valves (suction and delivery);
• Suction and delivery pump and circuits cooled.
a. Disconnect the suction and delivery pipes of the pump uid.
b. Disconnect the compressed air supply pipe from the pump.
c. Disassemble and remove the pump from the place of installation using suitable
lifting equipment.
CAUTION: risk of leakage of the washing and/or contaminated liquid; risk of injuries
and/or harm to health. The pump is not self-draining, pay attention during handling and disassembly.
If toxic, noxious or other types of health harming products have been used, the pump must be suitably
treated and washed before it is stored or sent.
 Separate the pump components by type and homogeneous materials (see Section 2.2).
CAUTION: risk of internal back-pressures and projection of components during disassembly.
In severe conditions (incorrect installations and/or stops and/or in stall conditions), residual pressures inside
the pump can be generated which are not discharged. Before opening and disassembling the pump, it is
necessary to secure the pump casings with a suitable ratchet strap and wear suitable Personal Protective
Equipment (PPE).
 For the disposal, contact Specialised Companies.
CAUTION: danger of pollution and/or accidents.
Make sure that no small or large components are dispersed in the environment which may cause pollu-
tion, accidents or direct and/or indirect damage.
The pump demolition and disposal is completed.