DeDietrich AMC 15 User Manual

DeDietrich AMC 15
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #88 background imageLoading...
Page #88 background image
Code Text display Description Adjustment range 10 15 25 25/28
MI
35
AP080 Frost min out
temp
Outside temperature below
which the antifreeze
protection is activated
-60 °C - 25 °C -10 -10 -10 -10 -10
AP091 Outside Sens.
Source
Type of outside sensor
connection to be used
0 = Auto
1 = Wired sensor
2 = Wireless sensor
3 = Internet measured
4 = None
0 0 0 0 0
AP108 OutsideSensorEn
abled
Enable the function Outside
Sensor
0 = Auto
1 = Wired sensor
2 = Wireless sensor
3 = Internet measured
4 = None
0 0 0 0 0
Tab.64
On > > Installation Setup > CU-GH08 > Auto filling CH > Parameters, counters, signals > Parameters
Code Text display Description Adjustment range 10 15 25 25/28
MI
35
AP006 Min. water
pressure
Appliance will report low
water pressure below this
value
0 bar – 6 bar 0.8 0.8 0.8 0.8 0.8
AP014 Auto Filling Setting to enable or disable
the automatic refill device. It
can be set to auto, manual
or off
0 = Disabled
1 = Manual
2 = Auto
1 1 1 1 1
AP023 Filling Inst
Timeout
Maximum time the
automatic filling procedure
may last at installation
0 Min – 90 Min 10 10 10 10 10
AP051 Filling Interval The minimum time that is
allowed between two top-up
fillings
0 Days – 65535 Days 90 90 90 90 90
AP069 Top up timeout Maximum time the
automatic topping up
procedure may last
0 Min – 60 Min 2 2 2 2 2
AP070 Operational
Pressure
The operational water
pressure the device should
be working on
0 bar – 2.5 bar 1.5 1.5 1.5 1.5 1.5
AP071 InstallMaxTimeOu
t
Maximum time that is
needed to fill the complete
installation
0 Sec – 3600 Sec 840 840 840 840 840
Tab.65
On > > Installation Setup > CU-GH08 > Shower time function
Code Text display Description Adjustment range 10 15 25 25/28
MI
35
DP357 ShowerZone T
warning
Time before Shower Zone is
warning
0 Min – 180 Min 0 0 0 0 0
DP367 ShowerZoneTime
Action
Action when Shower Zone
time has elapsed
0 = Off
1 = Warning
2 = Reduce DHW set
point
0 0 0 0 0
DP377 DHWred
Showerlimited
Reduced DHW setpoint
during shower limitation of
the zone
20 °C – 65 °C 40 40 40 40 40
9 Settings
88 AMC 7686707 - v.01 - 06092018