DIAGNOSTIC MODE
The alarm has a diagnostic function with three different modes. The rst diagnostic mode is
accessed by entering PIN-code 2-2-2-2-2. The LED will ash and the siren will beep once. The
alarm is now in diagnostic mode 1. If the button on the window module is pushed in mode 1
the alarm enters mode 2 and the siren beeps two times, and another push on the button enters
mode 3 with the siren beeping three times. If the button is pushed in mode 3 the alarm returns
to the rst mode again. Diagnostic mode is exited by turning of the ignition.
Mode 1
Open Door Indication The LED will start ashing when a door, trunk or hood is opened. When
the door, trunk or hood is closed or left open for more than 10 seconds the LED will turn off.
Mode 2
Alarm Log Indication – The LED will indicate the last ten alarm triggers starting with the most
recent trigger. There is a 5 second interval between each trigger indication. If there are no
triggers in the alarm log the LED will ash to indicate this.
1 blink – Level Sensor Warning
2 blinks – Level Sensor
3 blinks – Door
4 blinks – Hood
5 blinks – Trunk
6 blinks – Ignition
7 blinks – Aux
8 blinks – Motion sensor
9 blinks – Glass Break Sensor
10 blinks – Glass Break Sensor Warning
Mode 3
Motion Sensor Sensitivity Test The LED will stay on for 20 seconds when the Motion Sensor
is being armed. When the LED turns off the motion sensor is ready to be triggered. When
movement is detected the LED will ash briey and the siren will indicate the current motion
sensor sensitivity. The sensor is ready to be triggered again 1 second after the last beep.
REMOTE CONTROL
The alarm system can be operated by DEFA remotes. To add remote controls to the central
unit follow the procedure for entering PIN-code. After the correct PIN is entered press both
buttons on the remote at the same time. The siren will chirp and the led and lights will ash
to conrm that the remote is stored. If you wish to store more than one remote, both buttons
must be pushed on the second as soon as the rst remote is stored. You may store up to 4
remotes in the central unit.