2
Introduction
Introduction
Principles of Operation
F probes use the magnetic principle to measure the thickness
of non-magnetic coatings on ferrous metals.
N probes use the eddy current principle to measure the
thickness of non-conductive coatings on non-ferrous metals.
FN probes combine the full abilities of both the "F" and "N"
probes.
Throughout this manual, the symbol indicates more
information about the particular topic or feature is available on our
website. Go to: www.defelsko.com/manuals
NOTE:
Certification
All probes include a Certificate of Calibration. For organizations
with re-certification requirements, gages may be returned at
regular intervals for calibration. DeFelsko recommends that
customers establish gage calibration intervals based upon their
own experience and work environment. Based on our product
knowledge, data and customer feedback, a one year calibration
interval from either the date of calibration, date of purchase, or
date of receipt is a typical starting point.
The PosiTector 6000 hand-held, electronic Gage non-
destructively measures the thickness of coatings on all metals,
quickly and accurately. A PosiTector 6000 consists of a Gage
body and probe (see pg.19).
Plastic Lens Shield
The LCD is covered with a thin plastic film for protection against
fingerprints and other marks during shipment. This film, while
usually removed before using the instrument, can be left in place
to protect against paint overspray. Replacements can be
purchased.
Wrist Strap
We recommend attaching and wearing the
supplied wrist strap.
W
1
2

Other manuals for DeFelsko PosiTector 6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DeFelsko PosiTector 6000 and is the answer not in the manual?

DeFelsko PosiTector 6000 Specifications

General IconGeneral
TypeCoating Thickness Gauge
TechnologyMagnetic Induction, Eddy Current
SubstratesFerrous and non-ferrous metals
Measurement Range0 to 60 mils (0 to 1500 µm)
Resolution0.1 μm (0.01 mils)
DisplayLCD
Power Source2 x AAA batteries
ConnectivityUSB, Bluetooth
UnitsMils, Microns
Weight140 g (without batteries)
Probe TypeIntegral or separate
Standards ComplianceISO 2178, ISO 2360