Management Procedure 2585 Rev. F
1
Management Procedure 2585
Revision: F
Date Issued: Feb 21, 2003
Date Revised: June 10, 2019
Calibration Procedure
DeFelsko Corporation
PosiTector UTG, UTG-STD, UTG-ME, UTG-
C, UTG-CA, UTG-CLF, UTG-CX, UTG-M &
UTG-P
Ultrasonic Thickness Gage
Table of Contents
1 Introduction and UUC Performance Requirements ............................................................................................ 2
Table 1-1 Measurement Ranges ......................................................................................................................... 2
2 Measurement Standards and Support Equipment Performance Requirements .................................................. 2
Table 2-1 UUC Accuracy Requirements and Description ................................................................................. 2
Table 2-2 Minimum Use Specification .............................................................................................................. 3
Table 2-3 Actual Equipment Specification ........................................................................................................ 3
Table 2-4 Calibration Environmental and Warm Up Requirements .................................................................. 3
3 Preliminary Operations ....................................................................................................................................... 3
4 Calibration Process ............................................................................................................................................. 4
5 Performance Requirements ................................................................................................................................ 5
Table 5-1 Performance Requirements and Calibration Data for PosiTector UTG ............................................. 5
Management Procedure Change Notice ........................................................................................................................ 6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DeFelsko PosiTector Series and is the answer not in the manual?

DeFelsko PosiTector Series Specifications

General IconGeneral
Data LoggingYes
Storage Temperature-4°F to 140°F (-20°C to 60°C)
ConnectivityUSB, Bluetooth
CalibrationAutomatic or manual
TypeCoating thickness gauge
Measurement PrincipleMagnetic Induction, Eddy Current, Ultrasonic
Unitsmils, microns, inches
PC InterfaceUSB
Power SourceRechargeable battery
StandardsASTM D7091, SSPC-PA 2