PAGE 3 OF 12
Electrical installation
(Model 521 only)
This appliance must be earthed and the
manufacturer and the seller do not
accept responsibility for any damage
due to incorrect installation or
electrical connection.
This appliance should not be connected
through an earth leakage system.
Refer to S.A.N.S. 10142
Connection to the power supply
This appliance has a ‘Y’ type supply cord
connection and must be installed by a
licensed electrician, who will ensure that
the stove is correctly connected and safely
earthed. The rated current is printed on the
serial number label attached to the stove
upper back panel.
.
The appliance must be connected to the
mains through an All pole isolating switch
which has a minimum clearance between
the contacts of 3 mm. in All poles.
A means for disconnection must be
provided in the fixed wiring.
Bake and 2 small plates
Grill and 2 small plates
3 Plates
Electrical installation (Model
501 only)
Push the electric plug into a 230V. 15A.
Earthed wall socket
The stove is a plug in model with a 15A.
power supply.
It is therefore not possible to use all the
elements at the same time.
Set the selector to the required position.
Do not set the knob to the unmarked
position.
WARNING: Under no circumstances should the bake element be
covered with aluminium foil. Nor should a pan or tray be positioned
directly above the bake element.
Doing so would reflect the heat from the bake element downwards. Heat
to the oven would be restricted and overheating of the space below the
element would result in damage to the oven enamel.